Skip to the record
Trusted by locals. Built for Noosa.

Original source · versioned page text

2. Town Planning Report

of 23

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                               line to the closest boundary
                               of habitable buildings and
                               child activity areas, as
                               follows—
                               a) 20m for transmission lines
                               up to 132kV;
                               b) 30m for transmission lines
                               between 133kV and 275kV;
                               and
                               c) 40m for transmission lines
                               greater than 275kV.
Water supply and               S3.1 & S4.1 For a Class 1        Alternate outcome proposed. Each
conservation                   building other than a            dwelling has a pool. Further water
O3 On-site water storage is    Detached house, outside a        storage is not necessary for fire
designed and operated to       reticulated water service        fighting purposes. It is noted that
support the efficient use of   area, a rainwater tank is to     this was not a requirement for the
water;                         be installed with the            adjoining Dual occupancy recently
                               following minimum storage        approved at 7 Ventura Ave
AND                            capacities—                      (MCU17/0521).
                                a) Where no more than 3
O4 On-site water storage is    bedrooms – 45,000 litres; or
adequate for occupants         b) Where more than 3
every day use and fire         bedrooms – 60,000 litres;
fighting purposes.             AND c) There is to be on the
                               lot a dam, swimming pool or
                               water tank accessible for use
                               by the fire brigade that
                               contains at least 5,000 litres
                               of water.
Erosion and sediment           No solution provided             Can comply. The site will
control O5 Development                                          implement erosion and sediment
does not cause erosion or                                       control measures during
result in transport of                                          construction.
sediments off-site.


Safety and security            S6.1 The building entrance is    Complies. Entry to both units is
O6 For Multiple Housing        clearly identifiable and         clearly visible from the street.
Types 2, 3 and 4, buildings    visible from the street,
and outdoor spaces are         footpath and driveway;           Complies. Access to each unit has
designed to protect the        AND                              clear sightlines to the dwelling
personal security and safety   S6.2 The internal path           entry and street.
of residents by allowing for   network has clear sightlines
natural surveillance.          to the dwelling entry and        Complies. Villa 1 gains access along
                               street access points; AND        the drive, Villa 2 gains access via a
                               S6.3 Visitors have direct        path across the front lawn.
                               access to the entrance
Log in to download the original file

2. Town Planning Report.pdf · 819 KB (small file)