12. Code Assessment
Performance outcomes Acceptable outcomes Comment
bushfire on hazardous materials quantities of Lawn mower fuel, LPG gas heating and
manufacturing or storing in bulk. oxygen cylinders (for medical use). These materials
will be appropriately stored on site.
Access and Evacuation Routes
PO6 AO6.1 AO6.1 – Complies
Roads provide for easy and safe The road layout provides for through-roads and avoids
The premises is located on a rural residential
evacuation of residents of premises cul-de-sacs and dead-end roads.
allotment, which has direct and existing external
and access by emergency services.
roads to the east, south and west of the site.
OR
AO6.2
The development has a perimeter road reserve with a
minimum width of 20 metres and maximum gradient of
12.5%.
OR
AO6.3
Cul-de-sacs or no-through roads are provided with fire
trails or access easements, which are capable of being
navigated by conventional vehicles and which link to
through roads.
AO6.4 Complies
AO6.4 Safe access and egress will be available at all times
Safe access and egress is available at all times to all of the for the purposes of an emergency vehicles and
development for emergency vehicles and personnel. personnel. The accesses have been assessed by TTM
traffic consultants and have been determined to be