12. Code Assessment
Performance outcomes Acceptable outcomes Comment
Firebreaks and fire access tracks
PO8 AO8.1 AO8.1 Not applicable
Firebreaks and fire access tracks Where development involves the creation of a new road
provide: and lots, a firebreak is provided by providing a
cleared road reserve not less than 20 metres wide and
maximum gradient of 12.5% around the perimeter of the
1. adequate access for fire subdivision, between the created lots and surrounding
fighting and other vegetated lands.
emergency vehicles; and
2. adequate access for the OR
evacuation of residents and
emergency personnel in an AO8.2
emergency situation. Fire access tracks are provided between the created lots
and surrounding vegetated land that:
1. have a cleared minimum width of 6 metres;
2. have a maximum gradient of 12.5%;
3. provide unbroken access for fire fighting
vehicles;
4. provide passing bays and turning areas;
5. are located within an access easement that is
granted in favour of Noosa Council and the
Queensland Fire and Rescue Service.
AO8.3
Bushfire management measures are carried out on the
subject property and not any adjoining property. AO8.3 Complies
No bushfire management measures are proposed at
this stage. Although should they be required, they
will not be undertaken on the adjoining land.