Proposal Report:   Other Change to a Development Approval for Visitor Accommodation Type 4 Conventional (hostel accommodation) over Lot
                   163 on RP897370 and Lot 164 on RP94566 and located at 102 and 106 Pacific Avenue, Sunshine Beach




Annexure D:                           Visitor Accommodation Code




                                                                                                                      Page | 1
Full text of the other 3 pages

Page 2

Proposal Report:    Other Change to a Development Approval for Visitor Accommodation Type 4 Conventional (hostel accommodation) over Lot
                    163 on RP897370 and Lot 164 on RP94566 and located at 102 and 106 Pacific Avenue, Sunshine Beach




Division—Visitor Accommodation Code
Table 14-33
                  Column 1                                        Column 2                                             Column 3
              Specific Outcomes                     Probable Solutions (if code assessable)                           Compliance

 14.63 Effects of use
 Electricity supply infrastructure
 O1 The development does not adversely             S1.1 No solution provided                         Complies
 impact on existing or future electricity supply
 infrastructure; AND
 O2 All uses and works maintain an adequate        S2.1 Development for uses adjacent to or          Not applicable
 safe distance from electrical infrastructure      within 50m of an existing electricity
 including substations, overhead powerlines,       substation incorporates noise attenuation
 power poles and transformers.                     measures to mitigate noise impacts; AND
                                                   S2.2 Buildings and structures (including
                                                   swimming pools, sheds, tennis courts and
                                                   outbuildings) are not constructed under
                                                   overhead electricity transmission lines, or
                                                   within electricity easements
 Scale
 O3 Visitor accommodation is at a scale and        No solution provided                              Complies – Proposal involves conversion of
 nature complementary and respectful to its                                                          existing 3 x 1 bedroom units into hostel type
 surroundings and does not unduly impact on                                                          accommodation. Externally the existing
 adjacent or surrounding land uses or the                                                            building will be renovated with minor
 amenity of the surrounding area                                                                     extensions proposed, however the original
                                                                                                     single storey small scale building will be
                                                                                                     retained. The conversion of the existing
                                                                                                     building and incorporation into the adjoining
                                                                                                     hostel effectively defines the hostel and
                                                                                                     encloses and orientates the communal
                                                                                                     recreation areas to the streetfront.

 Mitigation of noise impacts
 O4 Development is designed and sited to           S4.1 Visitor accommodation is not located         Complies – Pacific Avenue has a speed limit
 avoid adverse noise impacts associated with       along parts of the major road network which       of 60km/hr and 40km/hr during school hours.
 neighbouring noise sources by—                    have a legal speed limit of 80km/hr or above,
 a) locating the use away from major noise         and is setback 40m from the North Coast
 sources such as busy roads or rail corridors:     railway line.
 or
 b) applying appropriate noise attenuation
 measures into the development.
 Ancillary recreation uses
 O5 Ancillary recreation uses, such as             S5.1 If the use involves ancillary use of         Not applicable – no tennis court proposed.
 outdoor tennis courts and half netball courts,    outdoor courts including tennis courts, half
 do not have an adverse effect on the amenity      courts and netball courts—the use complies
 enjoyed by users of adjacent or nearby            with the requirements in Section 2 of PSP8
 premises nor do they cause unreasonable           Tennis and Other Courts; AND
 disturbance to local fauna through light          S5.2 A 3m wide landscaped buffer is
 emissions, by ensuring that lighting devices      provided between the tennis court and any
 are limited to those designed and installed       boundary of the site; AND
 to:                                               S5.3 Any lit tennis court or sports court is
 a) minimise light spillage on neighbouring        located at least 60m from the external wall of
 premises;                                         an existing or approved residential dwelling
  b) preserve an acceptable degree of lighting     on an adjacent or nearby lot (as measured
 amenity at the neighbouring premises;             from the centre line of the court); AND
 c) provide covers or shading around lights;       S5.4 The vertical illumination resulting from
 d) direct lights downwards;                       direct, reflected or other incidental light
 e) position lights away from possibly affected    emanating from the site does not exceed 8
 areas; and                                        lux when measured at any point 1.5m
 f) enable brightness of lights to be adjusted     outside the boundary and at any level from
 to low levels. AND                                ground level upward; AND
                                                   S5.5 Any flood lighting is restricted to the
                                                   types that give no upward component of light
                                                   where mounted horizontally (i.e. a full cut off
                                                   luminare).



                                                                                                                                   Page | 2

Page 3

Proposal Report:    Other Change to a Development Approval for Visitor Accommodation Type 4 Conventional (hostel accommodation) over Lot
                    163 on RP897370 and Lot 164 on RP94566 and located at 102 and 106 Pacific Avenue, Sunshine Beach


                 Column 1                                        Column 2                                             Column 3
             Specific Outcomes                     Probable Solutions (if code assessable)                           Compliance

 O6 Noise originating from the use of the         S6.1 The court is not used between the
 tennis court does not have a detrimental         hours of 10:00pm and 6:30am the following
 effect on the amenity of the area or cause       day.
 nuisance to neighbouring residents.
 Traffic and access
 O7 Safe vehicular access is provided to and      S7.1 Visitor Accommodation is directly             Complies - Existing access arrangements to
 from the site without adversely impacting on     accessible from a sealed road or a good            be retained.
 the safety of the road network;                  standard gravelled road; AND
                                                  S7.2 Driveways do not exceed a gradient of
                                                  1 in 4 (25%); AND
                                                  S7.3 Where the site gains access from part
                                                  of the Major Road Network, vehicle
                                                  manoeuvring areas are provided in
                                                  accordance with Section 3 of AS 2890.1
                                                  Parking Facilities (Part 1: Off-street
                                                  Carparking) so vehicles enter and leave the
                                                  site in a forward gear
 Water supply and conservation
                                                  S8.1 & S9.1 Where outside a reticulated            Site connected to water.
 O8 An adequate, safe and reliable water          water service area—
 supply is available to the premises. AND          a) a rainwater tank of a minimum capacity of
 O9 On-site water storage is designed and         4,000 litres is to be provided for each
 operated to support the efficient use of         accommodation unit; and
 water.                                           b) there is to be on the lot a dam, swimming
                                                  pool or water tank accessible for use by the
                                                  fire brigade that contains at least 5,000 litres
                                                  of water.
 Effluent disposal
 O10 The provision of an effluent disposal        No solution provided                               Site connected to sewer.
 system is provided to maintain acceptable
 public health standards and avoid
 environmental harm.
 Safety and security
 O11 For Visitor accommodation Type 4,            S11.1 The building entrance is clearly             Complies – existing reception to be utilised.
 buildings and outdoor spaces are designed        identifiable and visible from the street,
 to protect the personal security and safety of   footpath and driveway; AND
 residents by allowing for natural surveillance   S11.2 The internal path network has clear
                                                  sightlines to the dwelling entry and street
                                                  access points; AND
                                                  S11.3 Visitors have direct access to the
                                                  entrance without passing through private
                                                  open space areas
 Emergency access
 O12 For Visitor accommodation Type 2 or 4,       No solution provided                               Complies
 site design and layout ensures efficient
 access and egress for emergency vehicles

 Table 14-37 — Type 4 – Conventional (Visitor hostel)


 Siting
 O38 Visitor hostels are established close to     No solution provided                               Complies – proposal involves and expands
 natural attractions and urban services and                                                          existing successful hostel.
 facilities where they do not unduly impact on
 residential amenity.
 Scale
 O39 Visitor hostels are at a scale and           No solution provided                               Complies – use of existing single storied
 density compatible with surrounding land                                                            units ensures built form compatible with
 uses.                                                                                               surrounding residential uses.
 Privacy
 O40 Visitor hostels are designed to ensure       S40.1 Outdoor sitting areas, common rooms          Complies – Communal areas located to the
 privacy for occupants of the premises and        and recreational facilities are located at least   centre of the site away from adjoining land
 adjoining residential uses through—              10m from the property boundary of adjoining        uses.
 a) locating potentially noisy activity areas     land included in a residential zone; AND
 (communal open space, kitchen, dining and        S40.2 Windows, doors and balconies are             Complies
 facilities) internal to the development rather   located so as not to face windows, balconies



                                                                                                                                  Page | 3

Page 4

Proposal Report:    Other Change to a Development Approval for Visitor Accommodation Type 4 Conventional (hostel accommodation) over Lot
                    163 on RP897370 and Lot 164 on RP94566 and located at 102 and 106 Pacific Avenue, Sunshine Beach


                  Column 1                                       Column 2                                              Column 3
              Specific Outcomes                    Probable Solutions (if code assessable)                            Compliance

 than on the perimeter of the premises; and       or the private open space of adjoining
 b) avoiding overlooking of the windows or        residential premises which are less than 12m
 private open space of adjoining properties       away.
 Kitchen, bathroom and dining facilities
 O41 All guests and staff have access to—         No solution provided.                              Complies - new rooms have ensuites and
 a) internal bathrooms and sanitary facilities;                                                      access to existing common facilities.
 and
 b) common kitchen and dining facilities.
 Kitchen and dining
 O42 Kitchen and dining areas are large           S42.1 Kitchen and dining areas are not less        Complies – Existing kitchen is able to cater
 enough to accommodate all occupants and          than 5% of the hostel’s total gross floor area.    for additional patrons. Minor extension to
 have adequate kitchen and dining facilities.                                                        refrigeration required.

 Common rooms
 O43 A common room, sufficient in size to         S43.1 A common room with a minimum floor           Complies – Existing common areas and new
 accommodate 60% of occupants at any one          area of not less than 7% of the visitor            cinema and outdoor smoking area (DOSA)
 time, is provided.                               hostel’s total gross floor area is provided;       sufficient to cater for patrons of the site.
                                                  AND
                                                  S43.2 If the visitor hostel has a restaurant or
                                                  café, it is of a size to accommodate 50% of
                                                  the total occupants at any one time and is no
                                                  less than 5.5% of the total gross floor area.
 Communal sitting areas
 O44 Comfortable and useable outdoor sitting      S44.1 The outdoor sitting area has a               Complies – communal area in the centre of
 area is provided which receives natural          minimum area of 8% of the hostel’s total           the site and includes gardens and sitting
 sunlight and breezes.                            gross floor area and is oriented towards the       areas.
                                                  north.
 Reception areas
 O45 A reception area marks the entrance of       S45.1 The reception area has a minimum             Complies – existing reception area well
 the hostel and is clearly visible and            floor area of 12m2 and is visible from the         signed and weatherproof.
 weatherproof.                                    street; AND
                                                  S45.2 The reception area is undercover
                                                  providing shelter from inclement weather.
 Laundry and clothes drying facilities
 O46 Visitors and staff have access to            S46.1 A laundry provided on the premises           Complies – existing laundry able to be
 adequate laundry and clothes drying facilities   has a minimum floor area of 3% of the visitor      utilised and sufficient to cater for patrons.
 on-site.                                         hostel’s total gross floor area; AND
                                                  S46.2 An outdoor clothes drying area
                                                  receiving unrestricted sunlight for at least two
                                                  hours per day is provided on-site and is
                                                  accessible for the use of guests.
 Vehicle parking and access
 O47 The operation of a visitor hostel avoids     No solution provided                               Complies – Large buses do not service the
 the parking of buses that are associated with                                                       site. Flashpackers has an existing mini bus
 the use, and with a capacity of 30 persons of                                                       that collects patrons form the Noosa Junction
 more, within any street lower than a collector                                                      bus depot.
 road status.




                                                                                                                                    Page | 4

Used in these records

About this file

File size
29 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix D - Visitor Accommodation Code.pdf · 29 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.