Council archive · source document
Appendix D - Visitor Accommodation Code · 132007.2446.03
Attached to the e-mail Other Change application (Extension of Existing Visitor Hostel - 21 Beds) - 132007.2446.03.
Proposal Report: Other Change to a Development Approval for Visitor Accommodation Type 4 Conventional (hostel accommodation) over Lot
163 on RP897370 and Lot 164 on RP94566 and located at 102 and 106 Pacific Avenue, Sunshine Beach
Division—Visitor Accommodation Code
Table 14-33
Column 1 Column 2 Column 3
Specific Outcomes Probable Solutions (if code assessable) Compliance
14.63 Effects of use
Electricity supply infrastructure
O1 The development does not adversely S1.1 No solution provided Complies
impact on existing or future electricity supply
infrastructure; AND
O2 All uses and works maintain an adequate S2.1 Development for uses adjacent to or Not applicable
safe distance from electrical infrastructure within 50m of an existing electricity
including substations, overhead powerlines, substation incorporates noise attenuation
power poles and transformers. measures to mitigate noise impacts; AND
S2.2 Buildings and structures (including
swimming pools, sheds, tennis courts and
outbuildings) are not constructed under
overhead electricity transmission lines, or
within electricity easements
Scale
O3 Visitor accommodation is at a scale and No solution provided Complies – Proposal involves conversion of
nature complementary and respectful to its existing 3 x 1 bedroom units into hostel type
surroundings and does not unduly impact on accommodation. Externally the existing
adjacent or surrounding land uses or the building will be renovated with minor
amenity of the surrounding area extensions proposed, however the original
single storey small scale building will be
retained. The conversion of the existing
building and incorporation into the adjoining
hostel effectively defines the hostel and
encloses and orientates the communal
recreation areas to the streetfront.
Mitigation of noise impacts
O4 Development is designed and sited to S4.1 Visitor accommodation is not located Complies – Pacific Avenue has a speed limit
avoid adverse noise impacts associated with along parts of the major road network which of 60km/hr and 40km/hr during school hours.
neighbouring noise sources by— have a legal speed limit of 80km/hr or above,
a) locating the use away from major noise and is setback 40m from the North Coast
sources such as busy roads or rail corridors: railway line.
or
b) applying appropriate noise attenuation
measures into the development.
Ancillary recreation uses
O5 Ancillary recreation uses, such as S5.1 If the use involves ancillary use of Not applicable – no tennis court proposed.
outdoor tennis courts and half netball courts, outdoor courts including tennis courts, half
do not have an adverse effect on the amenity courts and netball courts—the use complies
enjoyed by users of adjacent or nearby with the requirements in Section 2 of PSP8
premises nor do they cause unreasonable Tennis and Other Courts; AND
disturbance to local fauna through light S5.2 A 3m wide landscaped buffer is
emissions, by ensuring that lighting devices provided between the tennis court and any
are limited to those designed and installed boundary of the site; AND
to: S5.3 Any lit tennis court or sports court is
a) minimise light spillage on neighbouring located at least 60m from the external wall of
premises; an existing or approved residential dwelling
b) preserve an acceptable degree of lighting on an adjacent or nearby lot (as measured
amenity at the neighbouring premises; from the centre line of the court); AND
c) provide covers or shading around lights; S5.4 The vertical illumination resulting from
d) direct lights downwards; direct, reflected or other incidental light
e) position lights away from possibly affected emanating from the site does not exceed 8
areas; and lux when measured at any point 1.5m
f) enable brightness of lights to be adjusted outside the boundary and at any level from
to low levels. AND ground level upward; AND
S5.5 Any flood lighting is restricted to the
types that give no upward component of light
where mounted horizontally (i.e. a full cut off
luminare).
Page | 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix D - Visitor Accommodation Code.pdfRelated documentApplication case desk ↗
About this file
- File size
- 29 KB (small file)
- File type
No other editions are linked here.