CONCRETE SWIMMING POOL NOTES

 
 

3-S12 TRIMMER BARS VARIES TO 13000mm
LAPPED 450 AS REQUIRED 1. FOUNDATION MATERIAL TO BE APPROVED BEFORE AGGREGATE BED iS LAID, FOUNDATION SAFE 15. THIS DESIGN IS NOT SUITABLE UNLESS ALL THE CONDITIONS SPECIFIED ARE MET, AND ALL
eis [VARIES j. ____ 512 @ 300 CTRS. MAX WALL HEIGHT 20n0mn) FLOOR TO WALL RADIUS 300 10 M0) $$ _—~-ste-r59 7 28 BEARING CAPACITY SHALL BE 120kPa. POOL SHALL NOT BE FOUNDED AT ANY POINT ON FILL CONSTRUCTION PROCEDURES ARE CARRIED OUT AS SPECIFIED. ANY VARIATIONS OR ALTERATIONS
“= MATERIAL. POOL WALL SHALL BE CONSTRUCTED AGAINST FIRM, UNDISTURBED, NATURAL GROUND MUST BE APPROVED BY THE ENGINEER, PRIOR TO CONSTRUCTION.
= = = = FOR DEPTHS AS NOTED ON DRAWING. ANY SOFT GR OTHERWISE UNSOUND FOUNDATION MATERIAL
“T T [— Tt SHALL BE COMPLETELY REMOVED AND REPLACED WITH CRUSHED ROCK, COMPACTED IN 150 LAYERS 16. THE STRUCTURE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING SAA CODES:-
TO 95% AT MDD AS DETERMINED BY AS1289 E1.1. AS2783 CONCRETE SWIMMING POOLS,

 
    
 
   

  
  

—-4—-+—-L4-

AS3600 CONCRETE STRUCTURES CODE,

SELECT AS3735 CONCRETE STRUCTURES FOR RETAINING LIQUIDS.

    
         

      

 

    

   
    

l | | # c| 2. BEDDING DEPTH DEPENDS UPON FOUNDATION MATERIAL:-
2 VWesey Lb tb tl beh HOH ee _ BACKFILL © A) 75mm BED IN LOAMY FOUNDATION MATERIAL
= 2 B} 150mm BED IN HEAVY CLAY OR ROCKY FOUNDATION. 47. STRUCTURAL GRADE DEFORMED REINFORCEMENT MAY BE USED IN PLACE OF Y BARS AS FOLLOWS:-
s| = an MATERIAL TO BE 20mm SIZE SCREENINGS. N12 @ 125 - S12 @ 90
s SI 2 N12 @ 200 - S12 @ 125
© S| 3. GROUND WATER PRESSURE TO POOL WALLS AND FLOOR SLAB TO BE RELIEVED BY ‘HYDROSTATIC’ Ni2 @ 300 - S12 @ 200
5 a VALVE AS DETAILED. SURFACE WATER 1S TO BE DIRECTED AWAY FROM POOL.
Q 3 48. EXCAVATION TO BE INSPECTED BY ENGINEER PRIOR TO PLACEMENT OF REINFORCEMENT.
< a « 4. THIS DESIGN 1S NOT APPLICABLE FOR CONSTRUCTION IN EXPANSIVE CLAY SOILS.
eR 49. REINFORCEMENT TO BE INSPECTED BY ENGINEER PRIOR TO PLACEMENT OF CONCRETE.
az e S. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH B.S.5337 - 1976 BRITISH STANDARD
Zsa CODE FOR THE STRUCTURAL USE OF CONCRETE FOR RETAINING AQUEOUS LIQUIDS, AS2783, AS3600 THE POOL SITE HAS BEEN INSPECTED BY US ON.............--
als di © AND AS3735. AND WE ADVISE THAT IT IS SUITABLE FOR THE CONSTRUCTION OF THIS POOL.
RzZ0 be KROA Ts | Et ot tot cb i dd bid Ld Eee" een ALL HORIZONTAL REINFORCEMENT AT
e@ 8 RRRRAARRA CORNERS MUST BE CONTINUOUS FOR 6 CONCRETING SHALL BE CARRIED OUT IN ONE CONTINUOUS OPERATION (SPRAYING INCLUDED). 9-512 BARS EACH WAY
20 GRAVEL BED 600 AROUND CORNER 600 MIN. BAR LAP (150 CTRS.) ADDITIONAL
REFER TO NOTE 2 BELOW J. THE CHARACTERISTIC COMPRESSIVE STRENGTH OF CONCRETE TO BE 32MPa AT 28 DAYS. THE
BACKFILL ANY OVER-EXCAVATION S12 @ 300 EACH WAY EFFECTIVE CEMENT CONTENT OF THE CONCRETE SHALL BE NOT LESS THEN 320kg PER CUBIC METRE.
TO RADI WITH WEAK-MIX
CONCRETE AS SHOWN a sie SOUND NATURAL GROUND LINE 8. IMMEDIATELY AFTER SPRAYED CONCRETE HAS BEEN PLACED, PROTECTION MUST BE PROVIDED FROM
ADDITIONAL S12 @ 300 O/A s2@ 300 IF AE REFER TO NOTE 1 BELOW DIRECT SUN AND WIND, BY SHADING AND SHIELDING TO PREVENT PREMATURE DRYING. CONCRETE TO
CTRS. STOP 600 FROM TOP OF EACH WAY eal S12 VERTICAL BARS AT BE THOROUGHLY WETTED AND KEPT WET CONTINUOUSLY, FROM INITIAL HARDENING FOR A MINIMUM 2-512 BARS EACH WAY
POOL AND LAP 450 TO FLOOR ADDITIONAL S12 AT 300 0/A CTRS. SKIMMER INLET CTRS. SHOWN ON SECTION OF 7 (SEVEN) DAYS. ALTERNATIVE METHODS OF CURING TO BE APPROVED BY ENGINEER. S
STOP 600 FROM TOP OF POOL AND x HYDROSTATIC VALVE
REFER MAIN DRAIN DETAIL LAP 450 TO FLOOR 9. VERTICAL FORMWORK, AS REQUIRED; TO REMAIN IN PLACE FOR A MINIMUM OF 2 {TWO} DAYS.

@20 MIN. GRAVEL

10. POOL SHOULD NOT BE FILLED FOR 28 (TWENTY-EIGHT) DAYS AFTER CONCRETING. INITIAL FILLING TO

BE AT A UNIFORM MAXIMUM RATE OF 2 {TWO) METRES HEIGHT IN 24 HOURS.

NS

        

MOTE OVERALL SIZE OF POOL TO BE APPROXIMATELY 13000 x 6000. DETAILS tk POOL WALLS NOT TO BE BACKFILLED FOR 28 (TWENTY-EIGHT) DAYS AFTER CONCRETING. a.
SHOWN ON THIS DRAWING GENERALLY APPLY TO RECTANGULAR OR UNIFORMLY 42. REINFORCEMENT SPECIFICATION TO AS1302. ALL REINFORCEMENT TO BE HOT ROLLED GRADE 410 SECTION PLAN

CURVED POOLS. UNUSUAL POOL SHAPES MAY REQUIRE SPECIAL CONSIDERATION

 

TEMPCORE DEFORMED BARS. MINIMUM DISTANCE BETWEEN LAPPED BARS TO BE 2 x BAR DIAMETER.
Y12 BAR LAPS TO BE 450mm. Y16 BAR LAPS (WHERE SPECIFIED) TO BE 600mm.

SKIMMER BOX DETAIL MAIN DRAIN DETAIL 120 at a3

13. WHERE POOL IS FOUNDED BELOW WATER TABLE OR IN EXCESSIVELY WET CONDITIONS, ADDITIONAL

 

SPRAYED CONCRETE POOL 120 at AB

LONGITUDINAL SECTION

1:20 at A3

DRAINAGE AND PRESSURE RELIEF SYSTEMS TO BE APPROVED BY ENGINEER PRIOR TO CONSTRUCTION.

14. ANY DISCONTINUITY IN SLOPE OR DIRECTION OF POOL FLOOR MUST HAVE ADDITIONAL REINFORCEMENT
AND DRAINAGE PROVISIONS AS SPECIFIED BY THE ENGINEER.

    
  

     
 

          

    
 

Drawn: KJV

Appro i 3

TROY PAULSEN / RPEQ: 6990

Date. JANUARY 2007|Scate. AS SHOWN

Job Ref No: Drawing No: |_Issue: |
sc-risa | 04 | - |

CONSULTING ENGINEERS
SUNSHINE COAST CORAL COAST

PO BOX 8S PO BOX 2052
MAROOCHYDORE QLD 4558 BAMDABERG OLD 4670
PALO? 3477 437 PH: 07 4154 745)
TAAL 03 18 19 ROR peontiaso4r7 arses

ENGINEERING pyva ABN 21112761510 ACN 12761510

Client: LEACH DEVELOPMENT GROUP
Project: PROPOSED RESIDENCE

Te POOL LAYOUT & DETAILS

    
     

1. This is the property of the engineer, and may not be used, copied,
of reproduced wholly, or in part without the express permission of
the engineer. Infringement in any way may resuit in legal action.

 
   

    
 
    

:

LOT 40 ASPERA PLACE,
NOOSA RETREAT

2. Figured dimensions take precedence over scaled.
3. Verify att dimensions on site.

            

Used in these records

About this file

File size
5.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0197 - MCU - Detached House DJ Leach Pty Ltd [As Published].pdf · 5.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.