TIE-DOWN LEGEND
* INDICATES M12 ANCHOR ROD
* INDICATES M10 ANCHOR BOLT
REQ'D: 120kN
PROV: 128kN
BRACING & ROOF FRAMING LAYOUT
1. This is the property of the engineer, and may not be used, copied,
oF reproduced wholly, or in part without the express permission of
the engineer. Infringement in any way may result in legal action.
2. Figured dimensions take precedence over scaled.
43. Verify all dimensions on site.
REFER TO ARCHITECTURAL SPECIFICATIONS
FOR ALL SET QUT DIMENSIONS, FINISHINGS,
FLASHINGS, WATERPROOFINGS, ETC.
Gi Py.
Client: LEACH DEVELOPMENT GROUP
CONSULTING ENGINEERS
Coast Project: PROPOSED RESIDENCE
SUNGCTINE
BAROOSE DORE OL 4s BUNDASERO
FAR GF S146 16
EMPBARE 222
ENGINEERIN
AB.N 21112761510
ROOF FRAMING AND TIE DOWN SCHEDULE WALL FRAMING SCHEDULE
ROOF BATTENS 4 IN B
38 x 50 F14 HWD @ 900 CTRS. FIXED TO TRUSSES WITH 1/75 No. STUDS 90 x 35 MGP12 @ 450 CTRS.
14 TYPE 17 SCREW TOP PLATES 2/35 x 90 MGP12Z
BOTTOM PLATES 35 x 90 MGP12
ROOF TRUSSES
ALL TRUSS TO MANUFACTURERS DESIGN AND SPECIFICATIONS @
INTERNAL {NON LOAD BEARING)
900 CTRS. MAX. STUDS 70 x 35 MGP10 @ 450 CTRS.
TOP PLATES 35 x 70 MGP10
GT - GIRDER TRUSS BOTTOM PLATES 35 x 70 MGP10
INTERNAL TRUSS CONNECTIONS SHALL BE AS SPECIFIED BY
MANUFACTURER
Ss
ul 90 x 35 KDFI7
L2 120 x 35 KOFI7
MAXIMUM SPAN | JAMB STUDS @
(mm} SIDE OF OPENING
1, BUILDER TO ALLOW FOR ALL TRUSS MANUF. REQUIREMENTS
PERTAINING TO TIE DOWN, BRACING AND SUPPORT
2. TRUSS LAYOUT SHOWN INDICATIVE ONLY TO BE CONFIRMED BY
MANUFACTURER AND SUBMITTED TO ENGINEER FOR VERIFICATION
PRIOR TO FABRICATION
13-—-110-»-35_KDF4F
L4 245 x 65 HYNE LGL
LS 230 x 65 HYNBEAM 17c
200 x 65 HYNE LGL
PIER CORE
ROOF BEAMS:
RBt 150 x 45 HYNE LGL. FIX 1-M12 HOLD DOWN ROD TO R.C. SLAB
EACH END
RB2 195 x 65 HYNEBEAM 17c. FIX SIMILAR TO RB1
RB3 175 x 50 F14 HARDWOOD. FIX SIMILAR TO RB1
RB4 265 x 65 HYNEBEAM 2%c. FIX 1-M16 HOLD ROD EACH END
NOTES
1. ALL TIMBER FRAMING SHALL GENERALLY BE IN ACCORDANCE
WITH AS1684(N3) TIMBER JOINT GROUP - J2 OR JD4 (U.N.O)
2. PROVIDE 1 ROW OF NOGGING @ 1350 MAX. (TYPICAL)
3. LOAD BEARING WALL PLATES AND STUDS SHALL NOT BE
TRENCHED, HOUSED OR NOTCHED UNLESS SPECIFICALLY
APPROVED BY THE ENGINEER
4. FIX TOP PLATE OVER LINTELS WITHIN 100 OF TRUSSES WITH
30 x 0.8 G.I. STRAP 6/2.8@ NAILS EACH END
5. GENERALLY PROVIDE M12 ANCHOR RODS @ CORNERS
ADJACENT TO OPENINGS AND @ 1200 MAX. CTRS (U.N.O)
ENGAGED PIER SIMILAR
1:10 at A3
COLUMNS
C1 BRICK PIER TO DESIGNERS SPEC. FIX AS DETAILED
GENERAL TIMBER NOTES
1. ALL EXTERNAL TIMBER TO BE DURABILITY CLASS 2 OR BETTER
IN ACCORDANCE WITH AS1720.1 AND AS1720.2. ALTERNATIVELY
THE TIMBER CAN BE ADEQUATELY TREATED IN ACCORDANCE
WITH AS1604
2. HARDWOOD TO BE DURABILITY CLASS 2, FREE OF SAPWOOD
PLYWOOD THICKNESS (mm)
Ss
TRESS| STUD SPACING
GRADE 450 600
F8 7 9
Fil 6 7
F14 4 6
F27 4 45
INDICATES 30 x 2.8@ NAILS
(SPACINGS AS SHOWN)
M12 ANCHOR ROD EACH END OF
BRACING PANEL (ALT. FOR
PANEL LENGTHS NOT LESS
+M10 ANCHOR BOLT @ 1200 THAN 900, M12 ANCHOR BOLTS
MAX. CTRS. MAY BE USED IF NAILING
SPACING ALGNG TOP & BOTTOM
PLATES IS REDUCED TO 50)
BRACING SCHEDULE
PLY/1.8
INDICATES A 1.8m LENGTH OF BRACING WALL SHEETED ONE SIDE ONLY WITH STRUCTURAL
PLY TO ACHIEVE 6.4kN/m RACKING RESTRAINT IN ACCORDANCE WITH MANUF. SPECS.
(NOTE: PROVIDE M10 COACH SCREWS EACH CORNER OF 600mm PANELS)
© — INDICATES M12 ANCHOR ROD THROUGH TOP PLATE TO FLOOR SLAB
x - INDICATES M10 ANCHOR BOLT THROUGH BOTTOM PLATE TO FLOOR SLAB
NOTE:
ALL INTERNAL BRACING WALLS TO BE SECURELY FIXED INTO CEILING / FLOOR
DIAPHRAGM IN ACCORDANCE WITH TYPICAL DETAILS (REFER THIS DRAWING)
PLYWOOD
70 x 35 FS BLOCKING EACH SIDE
OF TRUSS BOTTOM CHORD WITH
6/3.15H NAILS TO TOP PLATE
INTERNAL BRACING
WALL 2/30 x 0.8 GI. STRAPS WITH
6/2.8 NAILS EACH END
NAILING PLATES OR FRAMING ANCHOR
(LEGS NOT BENT) TO EITHER END OF
NOGGING 6/2.8% NAILS EACH FACE
6/3.15 NAILS THROUGH
BRACING WALL 70 x 35 FS SHEAR BLOCKS
TYPICAL INTERNAL - EXTERNAL TRUSSES BRACING WALL
BRACING WALL FIXING PERPENDICULAR TO WALL TRUSSES PARALLEL TO WALL
TYPICAL BRACING WALL CONNECTION DETAILS
NOTE: PROVIDE CONNECTIONS (AS APPROPRIATE) EACH END OF DESIGNATED INTERNAL BRACING PANELS
Approved: Oo
TZ
TROY PAULSEN / RPEQ: 6990
Te ROOF & BRACING Scate:
LAYOUT AND DETAILS
LOT 40 ASPERA PLACE,
NOOSA RETREAT
1-N16 CENTRAL
CONCRETE FILL
Fic = 20MPa
TYPICAL BRICK PIER DETAIL
Job Ref No: [ Drawing No: |
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0197 - MCU - Detached House DJ Leach Pty Ltd [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.