Development Application Part 2 Report/Plans 178 Eumundi Noosa Rd Noosaville - REC12/0014

of 46

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                               fl
                                                                                                                                 RECONFIGURING OF A LOT CODE
                                                                                                                       Performance Criteria and Acceptable Solutions


                                               PROBABLE SOLUTIONS                                                                                         COUNCIL        USE
PERFORMANCE CRITERIA                                                                     SOLUTIONS COMMENTS
                                               (IF CODE ASSESSABLE)                                                                                       ONLY
                                               (nnn)    Include lighting to pedestrian
                                                   and cycle pathways to local
                                                   government requirements and in
                                                   accordance       with    Australian
                                                   Standard 1583.1 Road Lighting -
                                                   Pedestrian area (Category P)
                                                   lighting.
010                                            S10.1                                               The subdivision layout is in accordance with the
The subdivision layout is designed to          Where there is no relevant approved                 layout identified in the Mediation Agreement (Ref:
facilitate linkages with adjoining sites       master plan, concept plan, or site                  2378 and 2379 of 2009) and Condition 7 of the
in the immediate area.                         analysis plan, subdivision design                   Court Order (Ref: 2379 of 2009).
                                               incorporates future road, street,
                                               cycleway and pedestrian path and
                                               open space connections to adjoining
                                               sites.
011                                                                                                The park dedication will provide a suitable buffer.
Where the lots are to be used for              No solution provided.
Industrial business or Commercial
business uses, the layout provides
for appropriate buffer areas, to
mitigate possible impacts on nearby
residences or other noise sensitive
uses.
012                                                                                         N/A    The site is not in the Rural Settlement Zone.
For lots in the Rural Settlement               No solution provided.
Zone-a sealed access to the nearest
urban settlement is available.
14.191 Water supply for fire fighting
013                                            S13.1                                        le,    Each lot will be provided with the required
An adequate and accessible water               Each lot is connected to a reticulated              services.
supply is provided for fire fighting           water supply that is reliable and
purposes.                                      conforms to Council's Standards; or
1    Solution:   3 = Acceptable Solution                                                                                                                           Appendix C
                 A/S = Alternative Solution                                                                                                        Reconfiguring of a Lot Code
                 N/A = Not applicable to this proposal

178 Eumundi Noosa Road, Noosaville                                                                                                                                     Page 9
Log in to download the original file

Development Application Part 2 Report_Plans 178 Eumundi Noosa Rd Noosaville - REC12_0014.pdf · 8.1 MB (large file)