                                                                                                                                       RECONFIGURING OF A LOT CODE
                                                                                                                             Performance Criteria and Acceptable Solutions


                                                   PROBABLE SOLUTIONS                                                                                      COUNCIL       USE
 PERFORMANCE CRITERIA                                                                         SOLUTIONS COMMENTS
                                                   (IF CODE ASSESSABLE)                                                                                    ONLY
                                                   S13.2                                                The site is in a service area.
                                                   For areas not in a water service area,     N/A
                                                   each lot has an accessible dam or a
                                                   dedicated water tank for fire fighting
                                                   and contains not less than 5,000 litres
                                                   per dwelling unit; and
                                                   S13.3                                      N/A
                                                   All tanks are fitted with a coupling
                                                   suitable for attachment to fire fighting
                                                   appliances.
1 14.192 Energy efficiency - Not applicable as the proposal does not involve community title or urban residential development.
 14.193 Infrastructure
 016                                               S16.1                                            3   Each lot will be provided with the required
 Each lot is capable of being serviced             All lots are connected to power supply               services.
 by appropriate levels of-                         and telecommunications services;
 (ooo)  water supply;                              and
 (ppp)  reticulated sewerage;
 (qqq)      stormwater drainage;
 (rrr) power supply; and
 (sss)    telecommunications; and
 017                                               S17.1                                            3   Each lot will be provided with the required
 The design and provision of public                For lots in urban settlements-power                  services.
 services     and    utilities,  including         supply       and      communications
 sewerage, water, electricity, street              infrastructure     are      provided
 lighting     and      telecommunication           underground; or
 services-                                         S17.2
 (ttt) meets the needs of users;                   For lots elsewhere-power supply
 (uuu)     ensures health, safety and              and communications infrastructure
       convenience of the community;               are provided underground unless-
 (vvv)     protects       the      natural         (zzz)   located in the Rural Zone or
       environmental values of the site                 Rural Settlement Zone and where

 1       Solution:   3 = Acceptable Solution                                                                                                                       Appendix C
                     A/S = Alternative Solution                                                                                                    Reconfiguring of a Lot Code
                     N/A = Not applicable to this proposal

 178 Eumundi Noosa Road, Noosaville                                                                                                                                  Page 10
                                                                   C
Log in to download the original file

Development Application Part 2 Report_Plans 178 Eumundi Noosa Rd Noosaville - REC12_0014.pdf · 8.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.