Council archive · source document
RFI - Revised Engineering Plans · MCU24/0153
Plans and drawings: the text below has words only, no drawings.
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
NOTES:
1. INTERNAL DRAINAGE PITS & PIPES
TO BE COORDINATED WITH SUITABLE
QUALIFIED HYDRAULIC CONSULTANT
7-1
10006.150 N
10007.357 N
10006.397 N
10001.890 N
9999.588 N
10010.860 N
10007.357 N
1-3
2-3
3-3
4-3
2-3
1-5
4980.911 E
4987.296 E
4996.311 E
4998.781 E
4998.750 E
4980.532 E
4987.296 E
STRUCTURE NAME & STRUCTURE NAME &
SETOUT COORDINATES SETOUT COORDINATES
FOR TRENCH DRAIN
FOR TRENCH DRAIN
SUMP FILED INLET
SUMP FILED INLET
SUMP FILED INLET
SUMP FILED INLET
DETENTION TANK
DETENTION TANK
REFER TO PLANS
REFER TO PLANS
EXISTING PIPE
STRUCTURE DESCRIPTION STRUCTURE DESCRIPTION
FOR DETAILS
FOR DETAILS
600 x 600
600 x 600
600 x 600
600 x 600
FINAL LOCATION OF TANKS TO BE
DESIGN SURFACE COORDINATED BETWEEN HYDRULIC
EXISTING SURFACE ENGINEER AND STRUCTURAL ENGINEER.
AEP1% HGL
AEP10% HGL
REFER TO NOTE 1
REFER TO NOTE 1
PIPE SIZE (mm) 225 225 225 225 PIPE SIZE (mm) 150
PIPE CLASS & TYPE PVC PVC PVC PVC PIPE CLASS & TYPE PVC
PIPE GRADE (%) 15.99% 3.59% 0.50% 0.50% PIPE GRADE (%) 10.24%
PIPE SLOPE (1 in X) 6.3 27.9 200.0 200.0 PIPE SLOPE (1 in X) 9.8
FULL PIPE VELOCITY (m/s) 0.25 0.72 0.78 0.54 FULL PIPE VELOCITY (m/s) 1.91
NORMAL DEPTH VELOCITY (m/s) 1.61 668.89 1074.93 1074.93 NORMAL DEPTH VELOCITY (m/s) 663.92
Qx = 0.013 !!! Qx = 0.021 !!! Qx = 0.021 !!! Qx = 0.011 !!!
PIPE FLOW (cumecs) 0.003 0.013 0.021 0.021 PIPE FLOW (cumecs) 0.011
CAPACITY FLOW (cumecs) 0.180 0.000 0.000 0.000 CAPACITY FLOW (cumecs) 0.000
DATUM RL 33.000 DATUM RL 33.000
HGL IN PIPE & HGL IN PIPE &
44.267
43.773
43.536
43.499
43.458
43.265
43.244
43.229
43.034
44.593
44.588
43.798
43.773
WSE IN STRUCTURE WSE IN STRUCTURE
FINISHED (& EXISTING) FINISHED (& EXISTING)
0.936 (46.806)
0.713 (45.649)
2.201 (43.862)
1.947 (43.820)
0.713 (45.649)
45.184
1.275 44.425
1.849 45.231
1.927 44.929
1.007 43.977
46.354
0.675 44.425
SURFACE LEVEL SURFACE LEVEL
DEPTH OF INVERT BELOW FSL DEPTH OF INVERT BELOW FSL
1.177
1.820
INVERT LEVEL INVERT LEVEL
44.249
43.150
43.713
43.383
43.028
43.002
42.982
42.970
42.800
44.534
43.150
43.750
43.713
29 IL 54.80
CHAINAGE CHAINAGE
11.409
16.604
18.916
-4.654
2.214
6.229
0.000
7.663
6.868m 9.195m 5.195m 2.312m 7.663m
LINE 3 LINE 5
North Point Approved Project Address Sheet Title
STORMWATER LONGITUDINAL SECTIONS
E WHITMORE 51 ELANDA STREET SUNSHINE BEACH QLD
RPEQ 31423
For and on behalf of RECOR Pty Ltd.
SHEET 2
Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
SCALE
1 0 1 2 3 4 5
(metres)
www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE A1
A 21/03/25 ISSUE FOR APPROVAL TVZ AY 1 : 100 (FULL SIZE) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
043 A
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK in the revision description. 20240127
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Revised Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.