Original source · versioned page text
Appendix G - Bushfire Hazard Assessment & Management Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment & Management Plan v1 NCES REF: J001050 Lot 3 on RP131369 – 96 Black Mountain Range Road, Black Mountain medium, high or very high potential bushfire intensity area by a distance that achieves a radiant heat flux level of 29 kilowatt per square metre or less at: 1. The building envelope, if identified at RaL stage, or 2. Where a building envelope is not identified, at all the lot boundaries. Compliance with Assessment Benchmark 4 can be attained where all allotments are sufficiently separated from the nearby forest hazard so that a radiant heat flux level at any point on the building envelope, or the lot boundaries where no building envelope is identified, does not exceed 29 kW/m². The output results from Plate 10 & 11 in Section 3.6 identify that a minimum setback of 21 & 29.3m is required to the edge of the adjoining VHC 24.1 vegetation to achieve the <29 kW/m² radiant heat flux acting on the proposed building envelopes. The Plan of Development provides a minimum 39m setback between the proposed building envelopes and the closest hazardous vegetation (VHC 24.1 Acacia Open Forest) to the south- west. 29.3m is the minimum separation required to ensure the proposed building envelopes on the Lots 1 & 2 are exposed to <29kW/m² radiant heat flux as per the Flamesol modelling presented herein. The extent of proposed separation comprises land within the lots and the adjacent Black Mountain Range Road reserve which is considered a reliable permanent low threat zone for the life of the development. To ensure the available separation is maintained for the life of the development all land between the building envelopes and Black Mountain Range Road inclusive of 10m distance around the future dwellings is to be maintained as a low threat low fuel load Asset Protection Zone. Vegetative conditions in the APZ are to be provided as detailed in Section 5.6 Landscaping. 5.3 Water Supply The availability of a reliable water supply for firefighting purposes is a vital tool in the defence of bushfire impact. Reticulated water supply is currently not available within the site nor proposed to be connected to the site. The proposed development will therefore require provision of a readily accessible on-site emergency static water supply in accordance with Assessment Benchmark 4 of the SPP Bushfire 2019. Assessment Benchmark 4 references the QFES 2019 Bushfire Resilient Communities document for information regarding appropriate static water supply. Section 9.1 of Bushfire Resilient Communities’ states: An appropriate static water supply (in bushfire prone areas where reticulated supply is not provided) to support effective emergency services response includes a water tank that is available solely for firefighting purposes and can be accessed by firefighting appliances. The water tank is to be provided within 10 metres of each building (other than a class 10 building), which: a) is either below ground level or of non-flammable construction; b) has a take-off connection at a level that allows the following dedicated, static water supply to be left available for access by firefighters: i.10,000 litres for residential buildings; It is therefore recommended that a dedicated 10,000 litres should be made available to the future dwellings on each of the proposed new lots and this volume should be reserved for firefighting purposes only. Plate 14 outlines an example of how this can be achieved. © 2022 22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.