Pel tie a Pel ne ; Column 3
Specific Outcomes Probable solutions {if code assessable) Compliance
, DAIVENAY
e Y 44 . Y ae yr’
Org : R 9 + 3+)
eet i Dp —
SS] — ities a . ‘ ; ; i A condition may be imposed in this regard if
c Py 7 TT Ts ee $5.1 Landscaping provided which allows adequate P y Bp 9
gE A | visibility for casual surveillance of public and semi- considered necessary.
, CUEAA. public spaces, including entrances and exits to
_ vision) sites and buildings, by:
— Rokruay a) planting trees which have clean trunks toa
, ; height of at least 1.8 m; and .
O5 The provision of landscaping is to a b) appropriately spacing shrubs at 1.2m ;
satisfactory standard ensuring that it does not horizontal centres, with a maximum height of
lead to opportunities for concealment and 0.75m, to avoid clumping and to retain
possible assault sites. sightlines.
S6.1 Street trees and trees in carparking areas wa: . ae .
achieve a maximum of 900mm clear trunk height a cone ey Neecsary in this regard if
for a 2.0m high tree at planting and are able to .
attain a clear trunk height of 1900mm on maturity;
S§6.2 All scrub planting to be a maximum height of sas : wo .
O6 Street trees and plantings in towns and 700mm from the road pavement (not top of kerb). A conten Necesean in this regard if
villages, carparks and other areas where 7
potential conflicts with vehicles and pedestrians _
are evident, are planted so as to maximise
vehicle and pedestrian safety.
Services and utilities : “
O07 Alt landscaping works maintain adequate | $7.7 Plant species used in landscaping adjacent to | A condition may be imposed in this regard. .
safe distance from services and utilities substations, or adjacent to or on efectricity
including substations, overhead powerlines, transmission line easements, are less than 4m high
power poles and transformers, street lamps, at maturity and do not encroach within 3m of a
stormwater catchment pits, and underground | substation boundary; .
services and utilities. OR ,
$7.2 For trees higher than 4m, trees are planted
at a distance from any part of an electricity ;
: transmission line at least equal to the expected
height of the tree at maturity (see Figure -2;
Figure -2See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
001511C5.001.pdfRelated documentPublic source context ↗
07/0799 - MCU - Multiple Housing Type 2 Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.