Council archive · source document
SUPERSEDED COMPILED Decision Notice [As Published] · 132004.5743.02
NOOSA COUNCIL IDAS Development Application Decision Notice 4 of 13
12. The proposed development shall have all kitchen, laundry and bathroom fittings that comply with the AAA
Water Conservation Rating System as defined by the AS/NZS 6400 (Water Efficient Products - Rating
and Labelling 2003) and AS/NZS 3500 (National Plumbing and Drainage Standard Part 1.2), with toilets to
comply with the AAAA Water Conservation Rating System. All tap ware and shower roses shall not
exceed a maximum flow of 9 litres per min. Dishwashers and washing machines are excluded from this
requirement.
13. A verification survey of the building is to be carried out by a Licensed Surveyor and a certificate lodged
with Council during construction and upon completion of work confirming compliance with the maximum
allowable building height as required by either the conditions of approval or the Planning Scheme.
14. Security in the form of a cash bond or trading bank guarantee to the sum of $15,000 must be submitted,
to secure performance of all conditions of this approval, prior to the issue of a Development Permit for
operational works. The cash bond or trading bank guarantee will be returned on performance of the
conditions of approval less any costs incurred by Council in respect of enforcing performance of this
permit.
15. The requirements of this development approval are to be effected, prior to the use of the premises.
Council reserves the right to call upon the bond or guaranteed sum referred to in this approval to effect
compliance with conditions.
16. The Development Permit for a material change of use of premises lapses if the use has not happened by
29 November 2010, unless an application to extend the currency is approved by Council.
17. The developer must obtain all of the other Development Permits referred to in the Decision Notice, prior to
obtaining a Development Permit for Building Works.
Land Development
Lot Amalgamation
18. All separate, adjoining lots that form part of this application shall be amalgamated into one undivided lot in
accordance with Section 3.7.3 of the Integrated Planning Act and the Plan of Survey submitted for
registration at the Land Titles Office. Proof of title being issued for the amalgamated lot shall be
submitted to Council prior to the issue of the Development Permit for Operational Works.
Vehicle Access
19. A vehicular access driveway to serve the development shall be constructed with a maximum width of 3.0m
from the existing kerb and channel in Douglas Street to the front property boundary and then widen within
the site to the full width of the entrance to the carparking area.
20. The driveway shall be designed and constructed to Council’s design standards and to grades that prevent
vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
without any level difference. Should any driveways be constructed to grades that do not comply with
AS/NZS 2890.1-2004, Council will require that the driveway be removed and reconstructed to levels that
do comply.
Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
21. All vehicles shall enter and leave the site in a forward direction.
Carparking
22. Carparking shall be provided within the site generally as shown on drawing number 61.04.52B dated 23
August 2007 by Will Franklin Design, except as modified herein.
23. A minimum of 3 covered car park spaces shall be provided on site, including 1 clearly defined visitor car
park spaces.
24. The car parking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004 for user
class 1A with allowance for vehicles to enter and leave the site in a forward gear and with a minimum
head clearance (headroom) at any point of 2.2m. In this regard the proposal plans shall be modified such
that:
i. the double carspaces shall have an overall width of 5.4m in accordance with 2.4.1(b)(ii) of AS/NZS
2890.1-2004 and
ii. the single carspaces shall have clearance to all walls and obstructions in accordance with figure 5.2
of AS/NZS 2890.1-2004 and
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@8805e436\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED COMPILED Decision Notice [As Published]Related documentApplication case desk ↗
About this file
- File size
- 56 KB (small file)
- File type
No other editions are linked here.