Skip to the record
Beware of cheap imitations.

Council archive · source document

SUPERSEDED COMPILED Decision Notice [As Published] · 132004.5743.02

of 13

Text shows just the words. Original shows the document exactly as it was published.

NOOSA COUNCIL IDAS Development Application Decision Notice                                                  4 of 13


12.   The proposed development shall have all kitchen, laundry and bathroom fittings that comply with the AAA
      Water Conservation Rating System as defined by the AS/NZS 6400 (Water Efficient Products - Rating
      and Labelling 2003) and AS/NZS 3500 (National Plumbing and Drainage Standard Part 1.2), with toilets to
      comply with the AAAA Water Conservation Rating System. All tap ware and shower roses shall not
      exceed a maximum flow of 9 litres per min. Dishwashers and washing machines are excluded from this
      requirement.

13.   A verification survey of the building is to be carried out by a Licensed Surveyor and a certificate lodged
      with Council during construction and upon completion of work confirming compliance with the maximum
      allowable building height as required by either the conditions of approval or the Planning Scheme.

14.   Security in the form of a cash bond or trading bank guarantee to the sum of $15,000 must be submitted,
      to secure performance of all conditions of this approval, prior to the issue of a Development Permit for
      operational works. The cash bond or trading bank guarantee will be returned on performance of the
      conditions of approval less any costs incurred by Council in respect of enforcing performance of this
      permit.

15.   The requirements of this development approval are to be effected, prior to the use of the premises.
      Council reserves the right to call upon the bond or guaranteed sum referred to in this approval to effect
      compliance with conditions.

16.   The Development Permit for a material change of use of premises lapses if the use has not happened by
      29 November 2010, unless an application to extend the currency is approved by Council.

17.   The developer must obtain all of the other Development Permits referred to in the Decision Notice, prior to
      obtaining a Development Permit for Building Works.
Land Development

Lot Amalgamation
18.   All separate, adjoining lots that form part of this application shall be amalgamated into one undivided lot in
      accordance with Section 3.7.3 of the Integrated Planning Act and the Plan of Survey submitted for
      registration at the Land Titles Office. Proof of title being issued for the amalgamated lot shall be
      submitted to Council prior to the issue of the Development Permit for Operational Works.
Vehicle Access
19.   A vehicular access driveway to serve the development shall be constructed with a maximum width of 3.0m
      from the existing kerb and channel in Douglas Street to the front property boundary and then widen within
      the site to the full width of the entrance to the carparking area.

20.   The driveway shall be designed and constructed to Council’s design standards and to grades that prevent
      vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
      without any level difference. Should any driveways be constructed to grades that do not comply with
      AS/NZS 2890.1-2004, Council will require that the driveway be removed and reconstructed to levels that
      do comply.
      Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
      footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
21.   All vehicles shall enter and leave the site in a forward direction.
Carparking
22.   Carparking shall be provided within the site generally as shown on drawing number 61.04.52B dated 23
      August 2007 by Will Franklin Design, except as modified herein.

23.   A minimum of 3 covered car park spaces shall be provided on site, including 1 clearly defined visitor car
      park spaces.

24.   The car parking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004 for user
      class 1A with allowance for vehicles to enter and leave the site in a forward gear and with a minimum
      head clearance (headroom) at any point of 2.2m. In this regard the proposal plans shall be modified such
      that:
          i. the double carspaces shall have an overall width of 5.4m in accordance with 2.4.1(b)(ii) of AS/NZS
             2890.1-2004 and
         ii. the single carspaces shall have clearance to all walls and obstructions in accordance with figure 5.2
             of AS/NZS 2890.1-2004 and




AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@8805e436\@[email protected]

Used in these records

About this file

File size
56 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED COMPILED Decision Notice [As Published].pdf · 56 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.