Minor Change Existing Approval 132004 5744 13 [As Published] · 132004.5744.13

of 17

Text shows just the words. Original shows the document exactly as it was published.

               8.     A minimum of 1 covered car parking space shall be provided for each of the ‘Villa’ dwelling
                      units and ‘Building A’ and ‘Building B’. The covered car parking spaces shall be in proximity
                      to the dwelling units to the reasonable satisfaction of the Council’s delegate.
               9.     The community centre shall be for residents of the retirement village and their visitors. The
                      community centre shall not be for use by the general public.
               10.    The caravan/boat storage parking area and the visitor parking, bin storage to Walter Hay
                      Drive shall maintain a 2 metre landscaped setback from Walter Hay Drive North at a
                      minimum.
               11.    All buildings shall maintain a 15 metre setback from the site's frontage to Walter Hay Drive
                      North and Eenie Creek Road, except for the following
                      a.      The depot building, which shall be set back a minimum of 6 metres from the front
                              boundary to Walter Hay Drive North;
                      b.      The covered car parking areas, which shall be set back a minimum of 3.8 metres from
                              Eenie Creek Road;
                      c.      The electricity substation, which shall be set back a minimum of 8.2 metres from Eenie
                              Creek Road;
                      d.      The maintenance shed, which shall be set back a minimum of 4.3 metres from Eenie
                              Creek Road
               12.    The proposed development shall comply with the noise management strategies contained in
                      the report “Noise Assessment Report Retirement Village corner Walter Hay Drive and Eenie
                      Creek Road, Noosa – Report No. 507 – 611 Revision 2” prepared by Noise Measurement
                      Services, dated 16 June 2005 and include a 2 metre high acoustic barrier constructed along
                      the complete length of the site frontages adjacent Walter Hay Drive. Heights of this acoustic
                      barrier are to be relative to the finished level of the unit’s minimum floor level with a minimum
                      superficial mass of 15 kg/m2.
               13.    On completion of the development, a certificate by an appropriately qualified acoustic
                      consultant shall be submitted to Council demonstrating that the development complies with
                      the noise condition.
               14.    All hot water systems installed shall be either solar systems; electric heat pump systems or
                      gas systems (LPG or natural).
               15.    To meet the needs of people across a range of abilities and ages and be adaptable for the
                      changing needs of people over time, all dwelling and accommodation units shall include the
                      following:
                      1.      Are wheel chair accessible;
                      2.      Are accessible by a lift for those units located above the ground floor;
                      3.      All doors are a minimum of 870 mm wide; and
                      4.      Hallways are a minimum of 1.2m wide; and
                      All entries into the dwelling unit and internal doorways, have no more than a 10mm change
                      in level; and
                      Has an accessible toilet and bathroom, complete with reinforced walls, that can be reached
                      along an accessible path; and
                      A window, no higher than 600mm from the floor is provided in at least 1 bedroom to allow a
                      seated person to look out of and open and close the window; and
                      All power points are placed up from the floor (minimum 600mm) and out from the corner
                      (minimum 500mm) to facilitate disabled access.
               16.    A verification survey of the building is to be carried out by a Licensed Surveyor and a
                      certificate lodged with Council at completion of the work confirming compliance with the



                                                                                                         Page 4 of 17
Document Set ID: 23615315
Version: 3, Version Date: 05/03/2025

Used in these records

About this file

File size
212 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Minor Change Existing Approval 132004 5744 13 [As Published].pdf · 212 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.