 7.       Size and location of Waste Storage Areas –
               a) The following matters will be considered in determining an appropriate size for waste
                     storage areas:
                           1. Types of waste and storage required:
                                • bins for putrescible waste;
                                • bins for recyclables;
                                • drums for waste cooking oils;
                                • bales for cardboard;
                                • bags or bins for green waste; and
                                • any other specialised waste storage bins needed, eg: medical waste; and
                                                                                                             Complies –
                           2. Sufficient space between waste storage bins to allow for manoeuvring and
                                washing of bins, where appropriate noting that the bin store must be large
                                                                                                             Details throughout
                                enough for the bins to sit next to each other, not behind each other.
                                                                                                             OWMP
               b) Adequate lighting needs to be provided to allow the usage of the bin store after dark
               c) Internal waste rooms should be well ventilated and have a smooth easily cleanable
                     floor
               d) Suitable drainage, with water discharging into a sewer drain, must be installed to
                     allow the washing of bins and a tap with hose connection available.
               e) Waste storage areas can be roofed or unroofed.
               f) Waste storage areas contain bunded and non-bunded areas depending on their size
                     and the type of waste to be stored. Where bunded areas are required:
                      1. waste oil containers must be stored within bunded areas; and
                      2. bins must be washed within the bunded area.
 8.       Screening of Waste Storage Areas - Waste storage areas are required to be screened and can         Complies – All refuse
          be attractively designed to minimise their visual impact on the streetscape and surrounding        storage is provided
          areas. Examples exist within our shire of such storage areas.                                      within enclosures.
 9.       Indoor Waste Storage –
          a) Waste and waste storage bins must not be placed:
                      1. where they may impede safe use of any exit, exit corridor, doorway or stairway;
                      2. under stairways; or
                      3. near any existing or potential heat source.                                         N/A – External
          b) Waste storage bins must be made of non-combustible materials.                                   enclosure provided.
          c) Indoor waste storage areas must:
                      1. be well ventilated;
                      2. be well lit; and
                      3. have “hazardous waste” and “no smoking” signs installed.
 10.      Design Standards for Vehicle Access – Within the development site:                                 Complies – Site
          a) design specifications must be sufficient to carry a wheel load of 7 tonnes per axle; and        designed for 12.5m
          b) turning circles are designed in accordance with AUSTROADS: design single unit truck/bus         buses, minimal
                (12.5 metres) template; and                                                                  reversing required.
          c) vehicles must be able to move in a forward direction at all times or be able to enter and
                exit the development in a forward direction; or
          d) a turning bowl or a “T” or “Y” shaped manoeuvring area is provided, which allows the
                vehicle to turn with no more than a three point turn; and
          e) for bin collection from within a building or structure:
                      1. height clearance must be sufficient to allow for safe travel and lifting for
                            vehicles and bins); and
                      2. the grade of access/egress ramps must not exceed 1:8.




Site: 5 – 13 Production Street, Noosaville                                                                                           24
Reference: 24BRW0157
Log in to download the original file

24BRW0157 OWMP Final.pdf · 7.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.