24BRW0157 OWMP Final
Item Requirement Compliance / Comment
7. Size and location of Waste Storage Areas –
a) The following matters will be considered in determining an appropriate size for waste
storage areas:
1. Types of waste and storage required:
• bins for putrescible waste;
• bins for recyclables;
• drums for waste cooking oils;
• bales for cardboard;
• bags or bins for green waste; and
• any other specialised waste storage bins needed, eg: medical waste; and
Complies –
2. Sufficient space between waste storage bins to allow for manoeuvring and
washing of bins, where appropriate noting that the bin store must be large
Details throughout
enough for the bins to sit next to each other, not behind each other.
OWMP
b) Adequate lighting needs to be provided to allow the usage of the bin store after dark
c) Internal waste rooms should be well ventilated and have a smooth easily cleanable
floor
d) Suitable drainage, with water discharging into a sewer drain, must be installed to
allow the washing of bins and a tap with hose connection available.
e) Waste storage areas can be roofed or unroofed.
f) Waste storage areas contain bunded and non-bunded areas depending on their size
and the type of waste to be stored. Where bunded areas are required:
1. waste oil containers must be stored within bunded areas; and
2. bins must be washed within the bunded area.
8. Screening of Waste Storage Areas - Waste storage areas are required to be screened and can Complies – All refuse
be attractively designed to minimise their visual impact on the streetscape and surrounding storage is provided
areas. Examples exist within our shire of such storage areas. within enclosures.
9. Indoor Waste Storage –
a) Waste and waste storage bins must not be placed:
1. where they may impede safe use of any exit, exit corridor, doorway or stairway;
2. under stairways; or
3. near any existing or potential heat source. N/A – External
b) Waste storage bins must be made of non-combustible materials. enclosure provided.
c) Indoor waste storage areas must:
1. be well ventilated;
2. be well lit; and
3. have “hazardous waste” and “no smoking” signs installed.
10. Design Standards for Vehicle Access – Within the development site: Complies – Site
a) design specifications must be sufficient to carry a wheel load of 7 tonnes per axle; and designed for 12.5m
b) turning circles are designed in accordance with AUSTROADS: design single unit truck/bus buses, minimal
(12.5 metres) template; and reversing required.
c) vehicles must be able to move in a forward direction at all times or be able to enter and
exit the development in a forward direction; or
d) a turning bowl or a “T” or “Y” shaped manoeuvring area is provided, which allows the
vehicle to turn with no more than a three point turn; and
e) for bin collection from within a building or structure:
1. height clearance must be sufficient to allow for safe travel and lifting for
vehicles and bins); and
2. the grade of access/egress ramps must not exceed 1:8.