Table 2 - Div 6 Residential Use Codes [As Published] · 132007.2398
column 1 column 2 column 3
Specific Outcomes Probable solutions (if code assessable) Design Response/comments
maintained from the electricity transmission line
to the closest boundary of habitable buildings
and child activity areas, as follows—
a) 20m for transmission lines up to 132kV;
b) 30m for transmission lines between 133kV
and 275kV; and
c) 40m for transmission lines greater than
275kV.
14.53 Environmentally Sustainable Building Design
Hot Water Systems17 S3.1 All hot water systems installed are— Solar hot water systems will be provided to each
O3 Hot water systems are installed and operated a) solar systems; or detached dwelling unit and to each duplex unit.
to support the efficient use of natural resources Natural gas will be used for heating in the case of
b) electric heat pump systems; or
and minimise consequent pollution such as the care facility and the apartment buildings.
c) natural gas or LPG systems; or
greenhouse gas emissions.
17
This does not apply to buildings which qualify as Class 1A d) any combination of a), b) or c).
or 1B structures under the Building code of Australia
Water supply and conservation S4.1 If in a designated rainwater tank area as An alternative solution to individual rainwater
O4 On-site water storage is designed and identified in Map 1 of Schedule 8, residential tanks is proposed for the site – refer to attached
operated to support the efficient use of water; uses that qualify as class 1A or 1B structures engineering report.
under the Building Code of Australia have a
AND
rainwater tank or tanks in accordance with
O5 On-site water storage is adequate for Schedule 8.
occupants every day use and fire fighting
AND
purposes.
S5.1 Where not in a water service area a
rainwater tank of a minimum of 60,000 litres is
provided for each dwelling unit, with the
exception of Multiple Housing Type 1.
Erosion and sediment control No solution provided. The role and function of the existing dams is to
O6 Development does not cause erosion or Advisory Note be extended to assist in the treatment and
result in transport of sediments off-site. Persons undertaking development, including building work, detention of stormwater runoff – refer to
are required under the Environmental Protection (Water) stormwater management plan.
Policy 1997 (EPP) to ensure that sediment and other material
including building waste, sawdust, concrete, cement or paint
are not deposited or released into a roadside gutter,
stormwater drain or waterway, or into a place where it could
reasonably be expected to move or be washed into a
roadside gutter, stormwater drain or waterway and are not
washed from the site. Council enforces the EPP and
penalties may apply.
Table 2 – Code Compliance Checklists – Residential Uses Code 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Table 2 - Div 6 Residential Use Codes [As Published]Related documentApplication case desk ↗
About this file
- File size
- 168 KB (small file)
- File type
No other editions are linked here.