Skip to the record
Beware of cheap imitations.

Council archive · source document

Table 2 - Div 6 Residential Use Codes [As Published] · 132007.2398

of 10

Text shows just the words. Original shows the document exactly as it was published.

                    column 1                                                        column 2                                                  column 3
                Specific Outcomes                               Probable solutions (if code assessable)                              Design Response/comments
                                                               maintained from the electricity transmission line
                                                               to the closest boundary of habitable buildings
                                                               and child activity areas, as follows—
                                                               a) 20m for transmission lines up to 132kV;
                                                               b) 30m for transmission lines between 133kV
                                                                    and 275kV; and
                                                               c) 40m for transmission lines greater than
                                                                    275kV.
14.53 Environmentally Sustainable Building Design
Hot Water Systems17                                            S3.1 All hot water systems installed are—                      Solar hot water systems will be provided to each
O3 Hot water systems are installed and operated                a) solar systems; or                                           detached dwelling unit and to each duplex unit.
to support the efficient use of natural resources                                                                             Natural gas will be used for heating in the case of
                                                               b) electric heat pump systems; or
and minimise consequent pollution such as                                                                                     the care facility and the apartment buildings.
                                                               c) natural gas or LPG systems; or
greenhouse gas emissions.
17
  This does not apply to buildings which qualify as Class 1A   d) any combination of a), b) or c).
or 1B structures under the Building code of Australia

Water supply and conservation                                  S4.1 If in a designated rainwater tank area as                 An alternative solution to individual rainwater
O4 On-site water storage is designed and                       identified in Map 1 of Schedule 8, residential                 tanks is proposed for the site – refer to attached
operated to support the efficient use of water;                uses that qualify as class 1A or 1B structures                 engineering report.
                                                               under the Building Code of Australia have a
AND
                                                               rainwater tank or tanks in accordance with
O5 On-site water storage is adequate for                       Schedule 8.
occupants every day use and fire fighting
                                                               AND
purposes.
                                                               S5.1 Where not in a water service area a
                                                               rainwater tank of a minimum of 60,000 litres is
                                                               provided for each dwelling unit, with the
                                                               exception of Multiple Housing Type 1.
Erosion and sediment control                                   No solution provided.                                          The role and function of the existing dams is to
O6 Development does not cause erosion or                       Advisory Note                                                  be extended to assist in the treatment and
result in transport of sediments off-site.                     Persons undertaking development, including building work,      detention of stormwater runoff – refer to
                                                               are required under the Environmental Protection (Water)        stormwater management plan.
                                                               Policy 1997 (EPP) to ensure that sediment and other material
                                                               including building waste, sawdust, concrete, cement or paint
                                                               are not deposited or released into a roadside gutter,
                                                               stormwater drain or waterway, or into a place where it could
                                                               reasonably be expected to move or be washed into a
                                                               roadside gutter, stormwater drain or waterway and are not
                                                               washed from the site. Council enforces the EPP and
                                                               penalties may apply.


Table 2 – Code Compliance Checklists – Residential Uses Code                                                                                                                  3

Used in these records

About this file

File size
168 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Table 2 - Div 6 Residential Use Codes [As Published].pdf · 168 KB (small file)