Council archive · source document
Table 2 - Div 6 Residential Use Codes [As Published] · 132007.2398
column 1 column 2 column 3
Specific Outcomes Probable solutions (if code assessable) Design Response/comments
14.54 Amenity and Built form
Safety and security S7.1 The building entrance is clearly identifiable Staff and service vehicle access to the residential
O7 For Multiple Housing Types 2, 3 and 4, and visible from the street, footpath and care facility is proposed to be taken from
buildings and outdoor spaces are designed to driveway; Lamonts Road. Visitor access will be provided
protect the personal security and safety of AND via the main entry from Trading Post Road.
residents by allowing for natural surveillance S7.2 The internal path network has clear Access to the retirement village will be provided
sightlines to the dwelling entry and street access off Trading Post Road.
points; The master plan provides for a hierarchy of roads
AND with clear pathway connectivity provided
throughout the site.
S7.3 Visitors have direct access to the entrance
without passing through private outdoor living S 7.3 is not applicable to the proposed
areas. development.
Emergency access No solution provided The internal roads have been designed to allow
O8 For Multiple housing Type 3, 4 & 5, site circulation for emergency vehicles.
design and layout ensures efficient access and Provision is made for ambulance access and
egress for emergency vehicles. parking at the residential care facility.
Separation of incompatible uses S9.1 Bedroom windows are at least 3m away The unit design and layouts allow for compliance
O9 Development is designed to minimise noise from shared driveways or carparking areas of with this requirement. However it is noted that
carrying between dwelling units or adjacent dwelling units or accommodation units. retirement villages are low traffic generators and
accommodation units by locating noise sensitive as such internal traffic movements are minimal
spaces such as bedrooms away from noise and speed restricted.
generating areas of the development, such as
carparking areas or mechanic plant and
equipment or recreational facilities.
Mechanical plant & equipment S10.1 Mechanical plant and equipment, including All mechanical plant will be located and screened
O10 Mechanical plant and equipment associated pool and spa pumps, pool heaters, air- to provide acoustic and visual treatments.
with Residential Uses are designed and located conditioning units and refrigeration units are—
so as not have an adverse impact on the visual a) where located at ground level, screened by
amenity of the site or surrounding areas. fencing 1.5m in height or dense vegetation of
at least 1.5m in width incorporating grouped
trees and shrubs with maximum separation
distance of 1m measured from the centre of
the plant; and
b) for Multiple housing Type 2, 3 & 4 are
visually integrated into the line and plane of
the building and roof design and do not project
beyond the height or width of the building
Table 2 – Code Compliance Checklists – Residential Uses Code 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Table 2 - Div 6 Residential Use Codes [As Published]Related documentApplication case desk ↗
About this file
- File size
- 168 KB (small file)
- File type
No other editions are linked here.