Council archive · source document
Netanya Refurb_GIA Issue Set_210407 · 51901.3614.02
Attached to the e-mail Generally in Accordance - Landscaping & Colour Palette - 51901.3614.02, 51901.3786.03, 51992.479.02, 51994.1249.02, 51994.1048.02 & MCU13/0081.02.
Very large file (20.9 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Original PDF page 10, section 1. The text section number identifies this passage in the reader.
REV DESCRIPTION DRN DATE
A MCU DA Issue MS 25.02.20
B MCU DA Issue MS 02.03.20
C MCU DA Issue MS 06.03.20
A B
D Client Revisions MS 14.04.20
E MCU DA MS 05.08.20
Information Response
F
G GIA Issue MS 07.04.21
C
C
525
G New Roof New Roof
5° 5°
Select new roof
sheeting to existing New powdercoated
aluminium Heka hood
Valley gutter
roof structure Replace existing screen with new 16 x 40 mm
Select 16mm glass roof powdercoated aluminium RHS batten screen,
sheeting to entry walkway only fully welded to intemediate 40 x 40 RHS
Line of window / wall Extend non-combustible Generally throughout: powdercoated aluminium frames
under shown dotted eaves & metal roof existing beach New 'PosiGlaze' balustrade system.
framing to structural umbrella, stand and End Base channel 75 mm off side
engineers detail table to be retained walls with stainless steel toprail
New 200 x 50 powdercoated
Remove existing FC cladding to aluminium awning frame with
New 'PosiGlaze' balustrade system.
Balcony, Party Wall between Building powdercoated 'timber-look'
aluminium battens under to End Base channel 75 mm off side
Existing Restaurant
CBR A & Building B. Check integrity of (no works)
new entry walkway walls with stainless steel toprail
existing wall. Make good all surfaces
BUILDING A BUILDING B
prior to select proprietary-type
G FL FL waterproof applied non-combustible
Fall
3°
New 100 x 50 powdercoated New roof over entry /
render & membrane paint system. Screen Screen aluminium pergola frames to exit stair and sanitary
SC-23 SC-22 ground level units facilites respectively
under under
FL
OVF OC OVF OC OC OVF OC
BAL-B3 BAL-B3 BAL-B3 AL Louvre BAL-B3 BAL-B3 BAL-B3 BAL-B4 BAL-B4 BAL-B4 AL Louvre BAL-B4 BAL-B4 BAL-B4
N-RWO GD N-RWO GD GD N-RWO GD GD N-RWO GD
U305 balcony EX-DP EX-DP EX-DP EX-DP EX-DP
U306 balcony U307 balcony U308 balcony U309 balcony U310 balcony GD U311 balcony GDU312 balcony U313 balcony GD U314 balcony GD U315 balcony GD U316 balcony GD
(new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish) (new tiled finish)
EX-DP EX-DP
EX-DP TL-07 EX-DP EX-DP EX-DP offsets offsets in offsets
fall
TL-07 TL-07
TL-07 TL-07 TL-07 in wall wall TL-07 in wall TL-07 TL-07 TL-07 TL-07
fall
fall
fall
fall
fall
fall
fall
fall
fall
fall
fall
TL-07
90
EX- 0
FL
HYD
New 200 x 50 powdercoated aluminium awning
frame with powdercoated 'timber-look'
FL
aluminium battens under to existing terrace
Ne
w
U305 U306 U307 U308 U309 U310 U311 U312 U313 U314 U315 U316
R
r
3° oof
tte
EX-DP in wall
gu
cia
Existing Units
fas
(no works)
led
CBR
ea
nc
Co
BAL-B2
FL
U304 terrace
(new tiled finish)
ct
Du
fall TL-07
N-RWO Comms.
GD Room
FL
TL-07
FL
EX-DP in wall
BAL-B2
N-
RWO
CBR
fall
U303 balcony Walkway Ne
(new tiled finish) w
(new tiled finish) R
r
3° oof
tte
U304 TL-07
gu
TL-07 BAL-02 BAL-02 TL-07 TL-07
D
1
cia
fall
L-0
FHR
Void Void Void
BAL-01
BAL-01
BAL-01
BAL-01
fas
Linen
BA
SETOUT POINT
led
BAL-02
GD
ea
EX-DP EX-COL EX-COL EX-COL EX-DP N-DP N-DP
Refuse
nc
EX-COL Suite 2,
Co
EX-DP BAL-01 BAL-01
D
BAL-B2
EX-DP in wall Existing
BAL-02
Existing falls
EX-COL Cnr Gard
Lift Core 01 Walkway
FL
to be maintained
A
TL-07
BAL-02 (new tiled finish) BAL-02 Alexand
U302 balcony EX-DP PO Box
O
(new tiled finish) EX-COL EX-COL EX- EX-COL EX-COL N-DP KEX
FHR
BAL-ST1
U303
BAL-ST1
DP P 07 54
R
TL-07
Existing
BAL-ST1
fall
(new tiled finish)
BAL-ST1
Lift Core 02 admin@
Walkway
N-RWO
Existing Units EX-COL
Select weatherboard EX-COL
K
GD
(no works) EX-COL
D cladding to subframe Existing Existing
fixed to existing
R
Fire Stair 01 Fire Stair 02 SUNCOAST RESORT BUSINESS CENTRE
BAL-B2
blockwork wall
EX-DP in wall SUITE 2 CNR GARDAK ST & SURF RD
A
N- TL-07
N-DP N-DP ALEXANDRA HEADLAND Qld 4572
RWO
U301 balcony PO BOX 6232 MAROOCHYDORE BC Qld 4558
P
(new tiled finish) Existing stainless steel mech. PH : 07 5443 5028 FAX:07 5479 2380
Select powdercoated riser to be retained. Provide
TL-07 New powdercoated New powdercoated ABN 23 123 917 724
fall U302 New slab-fixed frameless aluminium screen fixed aluminium 'Heka' sun
aluminium screen fixed
new stainless steel support
EMAIL: [email protected]
fall hood box surround to bracing connected to existing
glass balustrade with to stair / slab edge to stair / slab edge
GD window opening building. Include for sound
powdercoated aluminium dampers and anti vibration
uprights project
PROPOSED ALTERATIONS &
BAL-02
ADDITIONS TO EXISTING
RESORT BUILDING
EX-DP
for
EX-DP
NETANYA RESORT
U301 Existing Feature powdercoated
at
Fire Stair 03 aluminium placards fixed
to existing blockwork wall 75 HASTINGS STREET
EX-DP
in wall NOOSA HEADS
drawing
N-DP
NEW WORKS - SECOND FLOOR
Select powdercoated New 100 x 25 powdercoated
alum. 'Heka' sun hood aluminium screen fixed to wall /
surround to window slab edge
AS SHOWN
date 7/04/2021 drawn JP scale @A1
drawing no. 19021 SD20.02 revision G
B
Copyright of this document remains the See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
About this file
- File size
- 20.9 MB (very large file)
- File type
No other editions are linked here.