(new tiled finish) (new tiled finish) VP
REV DESCRIPTION DRN DATE
TL-08 TL-08 TL-08 TL-08 TL-08 TL-08 TL-08 TL-08 A MCU DA Issue MS 25.02.20
St
SK
SK
SK
air
B MCU DA Issue MS 02.03.20
DG
SK SK C MCU DA Issue MS 06.03.20
PO
TL-10
New bar and D Client Revisions MS 14.04.20
200 x 50 powdercoated Aluminium-framed shelving joinery unit E MCU DA MS 05.08.20
seat to shower, with S S
TL-10 aluminium portal frame, columns HW to future details HW Information Response
HW
TL-09 select tiled finish to
S
and beams to shower area, with S TL-10 TL-10 TL-10 S TL-10 F GIA Issue MS 07.04.21
TL-10 future details TL-10 TL-10
selected powdercoated laser cut Linen HW HW
feature screen to top and short Chute VP
St
St
sides to future details TL-10 VP VP
air
Vent VP
air
TL-09 TL-09 TL-09 TL-09
TL-09
TL-11 TL-10 TL-10 Shower
Gate Gate Gate Gate Gate
Shower Shower
TL-11 TL-11 Shower TL-11 Shower TL-11 Shower TL-11 Shower
TL-09
Gate
TL-09
New powdercoated aluminium FHR
For setout of all blockwork
gate and side screen to Walkway
recessed roof terrace entry walls, refer to CD40.00
Gate Gate
Shower BAL-R1 BAL-R1 BAL-R1
RHS
RHS RHS TL-11
600
FL
For setout of all
blockwork walls,
Fascia gutter
refer to CD40.00
New powdercoated New powdercoated
BAL-R1
aluminium 'Heka' sun aluminium 'Heka' sun
New Roof
SETOUT POINT New downpipe from roof N-RWO
(connect to
Void hoods over windows /
2°
Void hoods over windows / Void
gutter over to connect to EX-DP below) doors to units below doors to units below
TL-08 TL-08
BAL-R1
BAL-R1
existing outlet
BAL-R1
BAL-R1
FL
Fascia gutter CBR Fascia gutter
2200
approx. BAL-R1 TL-08
N-RWO
BAL-R1
FL CBR
approx.
3050 3100
2510
Existing OC
approx. CBR approx.
Slab edge and TI FL CBR
New Roof
New Roof
Lift Core 01 2400 TI
approx.
approx.
New frameless glass balustrade FL
2410
2410
1525 1525 hob as per struct. approx. FL TL-08 FL
2°
2°
with anodised aluminium eng's. details Slab edge and Slab edge and
uprights and handrail, fixed to 1060 Line of laundry 1075
hob as per struct. hob as per struct.
new new hob over existing roof wall under
16
eng's. details eng's. details Generally throughout:
450
16 RHS
450
slab to future details RHS RHS
FL RHS
BAL-R1 FL BAL-R1
15 - New render and paint finish to all external walls
300
15
300
N-COL N-COL Fascia gutter
Screen
SC-08
14
Feature anodised aluminium 14 - New anodised aluminium (25µm coating)
300
approx.
approx.
300
Screen
placards and resort signage fixed 1995
SC-14
13 3
BAL-ST1
13 sliding doors to terraces / balconies
445
410
3 Provide 50 - 75 mm
7 eq. goings
Provide 50 - 75 mm
7 eq. goings
to existing blockwork wall
BAL-ST1
approx.
12 contrasting nosing contrasting nosing 4
approx.
12
- New anodised aluminium (25µm coating) windows
1995
4
1995
1975
BAL-ST1 strip to all stair treads Lift 02 strip to all stair treads
1800
11 5 11
BAL-ST1
5
Extension as per AS1428.1 - New frameless glass balustrade with
1800
Remove existing lift; new as per AS1428.1
1800
1800
10 6 10
machine-operated lift to 6 anodised aluminium (25µm coating) uprights
extend to roof terrace, lift 9 7
Reinforced concrete stair Reinforced concrete stair 7 9
N-COL treads and landings as per treads and landings as per - New tiles to walkways, terraces and balconies
shaft walls to be retained up 8 up
8 structural engineer's details FL structural engineer's details N-COL
TL-07 Fire Stair 01 New stair extension and New stair extension and TL-07
Fire Stair 02
approx.
Extension landing to have tiled finish landing to have tiled finish
1380
1380
TL-07, inc. treads and risers, TL-07, inc. treads and risers, Extension
R 1505 to NCC requirements in order to NCC requirements in order R 1500
RHS RHS
approx. to achieve R11 slip rating to achieve R11 slip rating approx.
Screen RHS Screen RHS
Parapet wall to roof,
SC-09 Remove existing lift; new SC-13
New roof structure over fire WT5 to match levels New roof structure over fire
N-DP Tier 1 type lift to extend N-DP
100
100
stair extension. Provide below. Provide parapet stair extension. Provide
to roof terrace. Lift shaft
roof cover for full extent of capping and apron roof cover for full extent of
walls to be retained
stair and bridge link flashing as required stair and bridge link
LEVEL 4 / ROOF TERRACE
Scale 1:50
Suite 2,
Cnr Gard
Alexand
PO Box
P 07 54
F admin@
200 x 50 powdercoated aluminium portal
New roof structure over lift New roof structure over lift New frameless glass balustrade
frame to future detail, supported by RHS New roof structure over fire stair New feature weatherboard New roof structure
extension walkway, supported New feature weatherboard wall extension walkway, supported with anodised aluminium uprights
columns with select powdercoated extension. Provide roof cover for wall cladding with select supported by RHS
by RHS columns below. Select cladding with select paint finish by RHS columns below. Select and handrail, fixed to new
'timber-look' aluminium battens over and full extent of stair and bridge link paint finish columns to walkway below SUNCOAST RESORT BUSINESS CENTRE
roof sheeting T.B.C. roof sheeting T.B.C. concrete hob on existing floor slab
50 x 50 SHS capping to top of frame SUITE 2 CNR GARDAK ST & SURF RD
ALEXANDRA HEADLAND Qld 4572
PO BOX 6232 MAROOCHYDORE BC Qld 4558
PH : 07 5443 5028 FAX:07 5479 2380
ABN 23 123 917 724
EMAIL: [email protected]
project
PROPOSED ALTERATIONS &
ADDITIONS TO EXISTING
RESORT BUILDING
for
NETANYA RESORT
at
75 HASTINGS STREET
NOOSA HEADS
drawing
DETAILED AREA - STAIR / LIFT
EXTENSIONS
AS SHOWN
date 7/04/2021 drawn JP scale @A1
drawing no. 19021 SD60.07 revision F
Copyright of this document remains the exclusive
N
property of SPROUT ARCHITECTS PTY LTD
ABN 23 123 917 724.
Contractors are to verify all dimensions and levels See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
About this file
- File size
- 20.9 MB (very large file)
- File type
No other editions are linked here.
Original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.