Original source · versioned page text
SUPERSEDED - Decision Notice - DBW23 0056 & RAP23 0010 [As Published]
CC103 D Roof Deck Plan prepared by Bennett 25 Sept 2023
Architects & Associates Pty Ltd
CC104 E Sections & Elevations prepared by Bennett 25 Sept 2023
Architects & Associates Pty Ltd
CC105 D Elevations prepared by Bennett Architects 27 Sept 2023
& Associates Pty Ltd
Amendments • The rooftop terrace is not approved and must be removed from
the plans.
• The balcony to the service access area is not approved and
must be removed from the plans
• The setback to the western boundary for the living kitchen,
pantry and laundry area must be increased to a minimum of 2m
for that section of building 4.5m high and above. Alternatively,
the building lowered to less than 4.5m for this area.
*(Refer to Advisory Note)
Building Height
4. The maximum height of the development must not exceed 8 metres above the ground level.
5. Certification must be submitted to Council from a Registered Cadastral Surveyor (Qld) which
certifies that the building does not exceed the maximum height requirement of this Decision
Notice.
Boundary Wall
6. The garage wall within the boundary clearance must not exceed 9 metres in length and have
a mean height* of not more than 3.5m
*(Refer to Advisory Note)
Performance Bond
7. Security in the form of a cash bond or trading bank guarantee to the sum of $5,000 must be
submitted to Council, to secure performance of all conditions of this approval, prior to the
issue of a Development Permit for Building Works. The cash bond or trading bank guarantee
will be returned on performance of the conditions of approval less any costs incurred by
Council in respect of enforcing performance of this permit. Council reserves the right to call
upon the bond or guaranteed sum to effect compliance with conditions.
Streetscape
8. Any shipping containers, railway carriages or similar must be placed behind the dwelling
house and not visible from the street.
Lighting Amenity
9. No flood lighting must be used on site. Any vertical illumination resulting from direct, reflected
or other incidental external lighting emanating from the site must not exceed 8 lux when
measured at any point 1.5 metres outside the boundary and at any level from ground level
upward.
Environment
10. Sediment or any other material including building materials or waste products must not be
deposited or released into the road reserve, stormwater drain or adjacent properties.
Landscaping Works
11. A minimum of 20% of the site must be retained as soft landscaping.
Page 3 of 8