Skip to the record
NoosaWatch™: The source of truth.

Original source · versioned page text

Cover Letter information Reponse - Auxilium Consulting

of 2
29 May 2026

Mr M Pinese
Planning and Development
Noosa Council
PO Box 141
Tewantin, Qld 4565


Dear Mr Pinese,

        Re:     RAL 26/0001 Information Request
        At:     25 Tulip St, Cooroy

With reference to the abovementioned development application and the Information Request from
Council dated 7 April 2026, we have prepared a response to the engineering matters raised as
follows:

Items 1-3. Legal Point of Discharge, location and sizing of Detention Tanks

The Stormwater Management Plan and modelling have been updated to address these items. An
assessment of the LPOD criteria utilising QUDM has been undertaken with the outcomes
incorporated into the development’s proposed stormwater management. This identified that no
actionable nuisance is occurring as there is no increase in stormwater quantities and/or velocities
that may arise in third-party damage. Interception and detention of generated flows and discharge
via a level spreader device ensures that no concentration of flows is occurring at the naturally
formed drainage channel existing throughout the greater catchment.


Item4. Assessment of RAL Code

Assessment of PO12 of the RAL Code is detailed below:

            Performance Outcome                                       Acceptable Outcomes
 PO12                                               AO12.1
 New lots are located, sized and configured so      All lots are connected to power supply and
 as to ensure each lot is capable of being          telecommunications services and where located within the
 serviced by appropriate levels of infrastructure   Urban boundaries, power supply and communications
 including:                                         infrastructure are provided underground.
      a. power supply;
      b. telecommunications; and                    Complies – the development is readily accessible to
      c. where within Local Plan Areas              connection to such reticulation and can be reasonably
      d. reticulated water supply;                  conditioned to comply.
      e. reticulated sewerage; and
      f. stormwater drainage.

                                                    AO12.2


                                                                                  Auxilium Consulting Pty Ltd
                                                                                         ABN 84 639 195 092
                                                                                             Bli Bli, Qld 4560

Log in to download the original (Cover Letter information Reponse - Auxilium Consulting.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 1 page

Page 2

                                              If located in a water service area each new lot can be
                                              connected to Unitywater’s water supply network.

                                              Complies – the development is readily accessible to
                                              connection to such reticulation and can be reasonably
                                              conditioned to comply.

                                              AO12.3
                                              If located in a sewerage service area each new lot can be
                                              connected to Unitywater’s sewerage network.

                                              Complies – the development is readily accessible to
                                              connection to such reticulation and can be reasonably
                                              conditioned to comply.

                                              AO12.4
                                              If located in a Local plan area lots can be connected to
                                              Council’s stormwater drainage network.

                                              Generally complies – the proposed development cannot
                                              achieve connection to the stormwater network via
                                              gravity due to the terrain and its position below the
                                              road’s kerb and channel. An acceptable outcome is
                                              achieved by assessing against the LPOD criteria in QUDM
                                              which determines that no actionable nuisance occurs if
                                              the stormwater quantities and/or velocities do not cause
                                              third-party damage. Therefore, utilising on site detention
                                              strategies and a level spreader device to the LPOD,
                                              compliance with QUDM and this PO is achieved.


                                              AO12.5
                                              If not in a sewerage service area each lot has sufficient
                                              area and other attributes to ensure efficient and effective
                                              on-site sewerage disposal.

                                              Not applicable


We believe that the above satisfactorily addresses the engineering matters raised however, should
additional information be required, please contact our office directly.

Yours sincerely,



Jaro Bauleka
Senior Engineer (Civil)

Encl
   1. Stormwater Management Report


                                                                              Auxilium Consulting Pty Ltd
                                                                                     ABN 84 639 195 092