Cover Letter information Reponse - Auxilium Consulting

of 2
                                              If located in a water service area each new lot can be
                                              connected to Unitywater’s water supply network.

                                              Complies – the development is readily accessible to
                                              connection to such reticulation and can be reasonably
                                              conditioned to comply.

                                              AO12.3
                                              If located in a sewerage service area each new lot can be
                                              connected to Unitywater’s sewerage network.

                                              Complies – the development is readily accessible to
                                              connection to such reticulation and can be reasonably
                                              conditioned to comply.

                                              AO12.4
                                              If located in a Local plan area lots can be connected to
                                              Council’s stormwater drainage network.

                                              Generally complies – the proposed development cannot
                                              achieve connection to the stormwater network via
                                              gravity due to the terrain and its position below the
                                              road’s kerb and channel. An acceptable outcome is
                                              achieved by assessing against the LPOD criteria in QUDM
                                              which determines that no actionable nuisance occurs if
                                              the stormwater quantities and/or velocities do not cause
                                              third-party damage. Therefore, utilising on site detention
                                              strategies and a level spreader device to the LPOD,
                                              compliance with QUDM and this PO is achieved.


                                              AO12.5
                                              If not in a sewerage service area each lot has sufficient
                                              area and other attributes to ensure efficient and effective
                                              on-site sewerage disposal.

                                              Not applicable


We believe that the above satisfactorily addresses the engineering matters raised however, should
additional information be required, please contact our office directly.

Yours sincerely,



Jaro Bauleka
Senior Engineer (Civil)

Encl
   1. Stormwater Management Report


                                                                              Auxilium Consulting Pty Ltd
                                                                                     ABN 84 639 195 092
                                                                                         Bli Bli, Qld 4560

Log in to download the original (Cover Letter information Reponse - Auxilium Consulting.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.