Council archive · source document
07/1017 - Op Works - landscaping, Acess &/or Carparking [As Published] · 142007.1017
17.000m(approx)
a n
New 150 connects to existing gully pit.
The connection is to be performedin
compliance with council approval.
o—
3,000 litre inground rainwater
storage tank and water reuse supply
to be equal to "Action Tanks" split
water SM —
First flush divertor and leaf (
po
Split system control box with.
a tomdfic mains water diversion,
contro} valve & dev.
throu 2 is to
the trap.
Fess polston chee te
charge
rougn a riser Section on
‘|
. “
cr
|
A |
|
; |
“t
Lo . yy
<=
© SE187
obrydary
Mini 225 wid
Win 292 wide lena
boundary ling 22.63Um
21.500m(approx)
exist spring ~
hydrant
SITE/LEVEL ONE PLAN-ALLSERVICES
Scale 1:100
+
ce (-)-% —.—
$B06/29/02
LL33.230
ee Connect to existing 100 kerb outlet.
3,000 litre inground rainwater
storage tank and water reuse supply
to be equal to “Action Tanks" split
water system.
First fl iyertor and |
First flush di Fo FEA ks".
f
Split system control box with
autometic m ips water diversion,
control valve |& dev.
Existing water meter.
NOTES-PLUMBING & DRAINAGE
1.AHl work is to comply with the Queensland Plumbing & Drainage Act 2002 and local authority requirements.
2. These drawings are diagrammatic only. Use dimensioned building construction plans for any set out
requirements.
3.Obtain all necessary approvals and pay all fees due.
4 The contractor is to visit the site to be fully aware of existing services and site conditions prior to
commencement of work.
5.Cold water pipework to be a minimum of 15mm@ to individual outlets and 2Omm@ or greater to more than
one outlet(uno)
6.Hot water pipework to be a minimum of 15mm%% (uno)
7.The contractor is to determine new drainage can be installed with correct grade and cover prior to
commencement of work.
8.All inground sanitary drainage shall be 100@ installed at minimum 1 in 60 grade.
9.Plumbing services that penetrate fire rated walls &floors must be installed to comply with the required
fire resistance level.
10.Backflow prevention devices to be installed as required by the local authority.
11. Water supply pipe sizes indicated on the drawings are equivalent to type “B" copper tube(refer table 1.1
of AS/NZS$3500.1). If using an alternative material the internal diameter of the pipe shall be equal to or
greater than that indicated on these drawings.
All hot water o ed primarily for personal hygiene purposes are to be temperature controlled to a
maximum of 50°C(uno).
NOTES-STORMWATER
1.All work is to comply with the Building Code of Australia, AS/NZS
3500.3 and local authority requirements.
2.These drawings are diagrammatic only. Use dimensioned building
construction plans for any set out requirements.
3.Obtain all necessary approvals and pay all fees due.
4.The contractor is to visit the site to be fully aware of existing
services and site conditions prior to commencement of work.
5.Stormwater drainage shall be installed at minimum grade of 1 in
100 (uno).
6.Inground stormwater drainage to be a minimum of 100mm@(uno).
ABBREVIATIONS
aav air admittance valve
b basin
cw cold water
dev double check valve
dp downpipe
dd drainage dropper
ej expansion joint
fsl finished surface level
fwg floor waste gully
he hose cock
hw heated water
hwu hot water unit
ios inspection opening to surface
il invert level
ll lid level
nts not to scale
org overflow relief gully ,
rpzd reduced pressure zone device ‘
sl surface level
shr shower
s sink
tg test gate
uno unless noted otherwise
we water closet
LEGEND
Sanitary drainage
/plumbing
Cold water —_— .
Heated water ae
Stored water
Stormwater drainage ——————————
Exist water see
Exist sewer -—— + es
| fan bradford
| pRimmblng consultants
PO BOX 334 PEREGIAN BEACH 04573
| PH (07) 54483875 FAX (07) 54483875
EMAIL - [email protected]
BSA LICENCE NUMBER:- 1027868
LICENCE CLASS:- HYDRAULIC SERVICES DESIGN
(INCLUDING ON SITE WASTEWATER MANAGEMENT)
PROJECT
PROPOSED DUPLEX DEVELOPMENT
18 DOUGLAS STREET
SUNSHINE BEACH
TALE
HYDRAULIC SERVICES
SITE/LEVEL ONE PLAN - ALL SERVICES,
NOTES - PLUMBING & DRAINAGE,
NOTES - STORMWATER,
ABBREVIATIONS, LEGEND
cuent DYNAMIC CAFES DWG NO REV
o7036-1 | A
A1 SCALE 1:100 U.N.O.
SHEET 1 OF >
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1017 - Op Works - landscaping, Acess &/or Carparking [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.