Council archive · source document
Attachment F - Geotechnical Report · 142007.743.04
J002100-001-L-Rev0
4 September 2023
Groundwater
No signs of groundwater or seepage were noted during our site walkover.
Surface Drainage
Based on observations of the ground conditions during the walk-over, the site is considered to be well
drained as expected, having a permeable dune sand profile.
Future site drainage from structures is expected to be directed towards the existing stormwater pits located
in the rear corners of the lot, which are then connected to the council stormwater system.
Vegetation
The proposed pool areas comprise short grass, with some trees more than 3 m high located along the
boundary lines and on the sloping bank just outside the rear boundaries (refer Photograph 5 above).
ASSESSMENT & RECOMMENDATIONS
Existing Conditions
The lot is mapped on the NC Landslide Hazard Overlay (susceptibility) as having area of Moderate and High
hazard at the rear of the site (refer Image 5). As the site is relatively flat, it appears that the Moderate and
High hazard ratings are associated with the cut batter along the western side of David Low Way, just east of
the rear site boundaries.
Image 5: Extract from NC Landslide Hazard Overlay.
Stability Assessment
The risk assessment has been carried out following the Australian Geomechanics Society ‘Landslide Risk
Management Guidelines’ (AGS 2007). Relative levels of risk and their implications are given in Table 2
below and the Qualitative Terminology for Use in Assessing Risk to Property is attached in Appendix B.
7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment F - Geotechnical Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.