Council archive · source document
Attachment F - Geotechnical Report · 142007.743.04
J002100-001-L-Rev0
4 September 2023
Table 2: Stability Risk Levels
Risk Level Example Implications
Unacceptable without treatment. Extensive detailed investigation and research, planning
VERY HIGH
VH and implementation of treatment options essential to reduce risk to Low; may be too
RISK
expensive and not practical. Work likely to cost more than value of property.
Unacceptable without treatment. Detailed investigation, planning and implementation of
H HIGH RISK treatment options required to reduce risk to Low. Work would cost a substantial sum in
relation to the value of the property.
May be tolerated in certain circumstances (subject to regulators’ approval) but requires
MODERATE
M investigation, planning and implementation of treatment options to reduce risk to Low.
RISK
Treatment options to reduce to Low risk should be implemented as soon as practicable.
Usually acceptable to regulators. Where treatment has been required to reduce the risk to
L LOW RISK
this level, ongoing maintenance required.
VERY LOW
VL Acceptable. Manage by normal slope maintenance procedures.
RISK
Note: 1) The implications for a particular situation are to be determined by all parties to the risk assessment and may
depend on the nature of the property at risk; these are only given as a general guide.
With reference to the qualitative measures of likelihood and consequence given in the attachment Qualitative
Terminology for Use in Assessing Risk to Property, failure of the cut batter along David Low Way is
assessed as Rare. (i.e. the event is conceivable but only under exceptional circumstances over the design
life). The Consequence to Property (residence and pool) of such an event occurring is assessed to be
Medium (i.e. moderate damage to the pool and/or significant part of the site requiring large stabilisation
works). A combination of these measures in the risk matrix results in a property risk classification of Low.
The assessment of Rare is based on the lack of evidence of past movement (no damage to existing road
pavement or kerb/channel); the site geology and slope (medium dense to dense sand; nearly flat site and cut
batter about 22°); and the relatively good drainage across the site and surrounds.
This level of risk is generally acceptable to regulators (i.e. NC) provided the recommendations given below
are followed.
To maintain a ‘Low’ risk classification, the following measures must be implemented for future construction:
Temporary cut batters are to be no steeper than 1V:1H. If loose sand or groundwater is encountered,
temporary dewatering and flatter batters will be required (e.g. up to 1V:3H). If required setbacks cannot
be achieved due to the proximity of site boundaries or existing structures, some form of temporary
retaining will be required.
Surface drainage measures must be installed to direct stormwater flow away from the pool (and
residence) towards a legal point of discharge (e.g. stormwater drains at rear of lot).
8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.