                                                  Table 13.12—Flood levels and flood immunity requirements
            Including amendments to 3 July 2017
The Noosa Plan



                                                                                                                                                         50
                                                       Type of development                                    Flood level (Define Flood Event ) for a 2100
                                                                                                              planning period
                                                       General
                                                       Business uses                                          1% AEP

                                                       Residential uses                                       1% AEP

                                                       Community Use                                          0.5% AEP
                                                       Education Type 1 Childcare, Type 2 School

                                                       Other uses, unless specified below                     1% AEP

                                                       Community Uses that are essential community infrastructure (recommended flood level)
                                                       Emergency service facilities, other than 0.2% AEP
                                                                      51
                                                       police station

                                                       Hospital and associated facilities                     0.2% AEP

                                                       Police facilities                                      0.5% AEP

                                                       Stores of valuable records or items of                 0.5% AEP
                                                       historic or cultural significance

                                                       Infrastructure Uses that are essential community infrastructure (recommended flood
                                                       level)
                                                       Major switch yards and substation          0.5% AEP
                                                                           52
                                                       Power facilities                                       0.2% AEP
                                                                                    53
                                                       Sewerage treatment plant                               0.01% AEP

                                                       Water treatment plant                                  0.5% AEP

                                                       Hazardous materials
                                                       Hazardous materials                                    1% AEP




                                                  50
                                                     The Defined Flood Event is the nominated recurrent event at the end of the nominated planning period.
                                                  51
                                                     Some emergency service and police facilities (e.g. water police and search and rescue operations) are dependent on
                                                  direct water access. The flood levels do not apply to these aspects but other operational areas should be located above the
                                                  recommended flood level to the greatest extent feasible
                                                  52
                                                     Some emergency service and police facilities (e.g. water police and search and rescue operations) are dependent on
                                                  direct water access. The flood levels do not apply to these aspects but other operational areas should be located above the
                                                  recommended flood level to the greatest extent feasible.
                                                  53
                                                     For a sewerage treatment plant the recommended flood level applies only to components that are likely to fail or may result
                                                  in contamination.

                                                                                                             13-50
                                                                                         Natural Hazards and Natural Resources Overlays
Log in to download the original file

2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB).pdf · 18.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.