column 1 column 2
Including amendments to 3 July 2017
Specific Outcomes Probable solutions (if code assessablecode
The Noosa Plan
assessment)
and requirements for the design and siting of
h) disturbance of buildings and features, effluent disposal systems where located
including natural features, of heritage outside a sewerage service area. Compliance
significance. with PSP24 will be considered as part of
Council’s assessment of the plumbing and
drainage application.
Table Error! No text of specified style in document.-22 — Service & Utility Type 2 - Installation
column 1 column 2
Specific Outcomes Probable solutions (if code
assessablecode assessment)
14.40 Effects of use
O9 Electricity transmission line easements are S9.1 A minimum separation distance is
managed to ensure— maintained from the electricity transmission
a) the continuation of the transmission of bulk line to the closest boundary of habitable
electricity; buildings and child activity areas, as
b) safety and amenity for residents, occupiers follows—
and land uses in close proximity; a) 20m for transmission lines up to
c) natural environmental values are not 132kV;
adversely impacted upon; and b) 30m for transmission lines between
d) the Shire’s visual and landscape qualities are 133kV and 275kV; and
not adversely impacted upon. c) 40m for transmission lines greater
than 275kV;
AND
S9.2 Only trees with a mature height of less
than 4m are planted within electricity
transmission line easements.
Table Error! No text of specified style in document.-23 —Service & Utility Type 3 - Tower
column 1 column 2
Specific Outcomes Probable solutions (if code
assessablecode assessment)
14.41 Effects of use
Visual amenity
O10 The tower is visually integrated with its S10.1 The tower is—
landscape or townscape setting so as not to be a) not established in the Detached
visually dominant or obtrusive. Housing, Semi-Attached Housing,
Attached Housing or Visitor Mixed Use
Zones;
b) camouflaged through the use of
colours and materials which blend into
the surrounding landscape; and
c) unobtrusive when viewed from any
17
part of the major road network; or
S10.2 The tower is co-located on an existing
telecommunication tower;
AND
17
PSP23 Telecommunication Towers provides guidance and information in relation to the installation of telecommunication
towers.
44
Infrastructure Uses Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB)Related documentPublic source context ↗Public source context ↗Public source context ↗
2017-06-06-p-e-agenda-attachment-1-to-item-6-draft-alignment-amendments-part-1-pages-1-907-pdfRelated documentPublic source context ↗
About this file
- File size
- 18.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.