Including amendments to 3 July 2017
Specific Outcomes Acceptable solutions (if self-
The Noosa Plan
assessableaccepted development subject to
requirements)
Probable solutions (if code assessablecode
assessment)
services and utilities appropriate to its setting. water or sewerage service area, appropriate
connection is provided to reticulated sewerage,
water supply and stormwater drainage.
Electricity supply infrastructure
O7 Uses and works maintain an adequate S7.1 Buildings and structures (including
safe distance from electrical infrastructure swimming pools, sheds, tennis courts or
including substations, overhead powerlines, outbuildings) are not constructed under
power poles and transformers. overhead electricity transmission lines, or within
electricity easements.
Water Supply Infrastructure
O8 Existing water supply infrastructure, S8.1 Buildings and structures are setback a
including pipeline corridor, is protected from minimum of 20m from a water supply pipeline
incompatible development to ensure the safety as shown on Overlay Map OM3.5.
and reliability of water supply network.
Steep Slopes and Landslide hazard areas
O9 Detached houses, Ancillary dwelling S9.1 If on premises identified as a Landslide
units, and associated uses are sited or Hazard Area on Overlay Maps OM1.3–9.3, or
constructed to maintain the safety of people and on steep slopes the use does not–
property from the risk of landslide. a) involve the removal of vegetation other than
grass from use areas; or
b) involve excavating or filling of more than
3
50m of material (other than placement of
topsoil not exceeding 100mm in depth
relative to natural ground level; or
c) involve cut or fill with a depth of more than
2m relative to natural ground level; or
d) redirect or impede water flows in an
existing watercourse or stormwater drain;
or
e) involve construction of an on-site effluent
disposal system;
OR
S9.2 A site specific geo-technical report
prepared by a registered professional engineer
either—
a) certifies that the site is not at risk from
landslide emanating from the site or from
other land; or
b) identifies methods of stabilising all
buildings, accessways and use areas;
AND
S9.3 If the geo-technical report identifies
methods of stabilising buildings, accessways
and use areas, those methods are
implemented.
Height
O10 Buildings and other structures— S10.1 The maximum building height in metres
a) are low rise and present a building height and storeys is—
consistent with structures on adjoining and a) if in the Visitor Mixed Use Zone – 12m
surrounding land; (but not exceeding 3 storeys); or
b) have a maximum building height of—
b) if in the Noosa Heads Locality, Attached
i) for Visitor Mixed Use Zone— 3
63
Detached House Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB)Related documentPublic source context ↗Public source context ↗Public source context ↗
2017-06-06-p-e-agenda-attachment-1-to-item-6-draft-alignment-amendments-part-1-pages-1-907-pdfRelated documentPublic source context ↗
About this file
- File size
- 18.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.