column 1 column 2
Including amendments to 3 July 2017
Specific Outcomes Acceptable solutions (if self-
The Noosa Plan
assessableaccepted development subject to
requirements)
Probable solutions (if code assessablecode
assessment)
Close Noosa Heads - 4 storeys; storeys);
Otherwise - 3 storeys; c) if in the Shire Business Centre Zone –
iii) if in the Shire Business Centre i. Precinct E1 or E2 - 12m (but not
Zone— exceeding 3 storeys);
Precinct E1 or E2 - 3 storeys; ii. Precinct REC/MU - 8m (but not
Precinct REC/MU - 1 storey; exceeding 1 storey);
iv) if in the Noosaville Locality and the d) if in the Noosaville Locality and the
Attached Housing Zone - 2 or 3 Attached Housing Zone and with frontage
storeys depending on the location to the following streets – Russell St,
of the site; William St and Howard St, or Weyba Rd,
v) otherwise - 2 storeys; James St and Albert St north of their
c) do not visually dominate the street, intersections with Elizabeth St (as well as
surrounding spaces or the existing skyline; properties fronting Gympie Terrace or
d) preserve the amenity of surrounding land Noosa Parade between Weyba Road and
including privacy, views and access to Russell Street)- 12m (but not exceeding 3
sunlight; storeys);
e) respect the scale of surrounding e) if in the Noosa North Shore Locality and in
vegetation; and the Detached Housing Zone – 8m or 9m
f) respond to the topography of the site by where the pitched roof, but no other part
stepping down the slope or sitting above of the building or structure, exceeds 8m
the ground level on stumps, for sloping (but not exceeding 2 storeys either way);
sites. f) if in the Tewantin Locality and the
Business Centre Zone – 10m (but not
exceeding 2 storeys);
g) if in the Rural Zone or Rural Settlement
Zone – 8m or 9m where the pitched roof,
but no other part of the building or
structure, exceeds 8m (but not exceeding
2 storeys either way); or
h) otherwise – 8m (but not exceeding 2
storeys).
Site cover
O12 The site cover of buildings and other S12.1 If involving a class 1 or class 10a
roofed structures— building within the Detached Housing Zone—the
a) is of a scale that is compatible with site cover does not exceed—
surrounding development; a) for a single storey building – 50%; or
b) does not present an appearance of bulk to b) for a building of 2 or more storeys – 50%
adjacent properties, roads or other areas on the ground floor and 30% for the second
in the vicinity of the site; storey(s) or 40% for all storeys for a
c) maximises the retention of existing building of 2 or more storeys;
vegetation and allows for soft landscaping
between buildings; OR
d) allows for adequate area at ground level S12.2 For other classes in the — Detached
for outdoor recreation, entertainment, Housing Zone – 40%
clothes drying and other site facilities; and
e) facilitates on-site stormwater management OR
and vehicular access. S12.3 If otherwise-
a) in the Semi-Attached Housing - 40%;
b) in the Attached Housing Zone –
i If in Sunshine Beach 35%; or
ii Otherwise – 35%
c) For the Community Services Zone – 50%
104
Building Works Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB)Related documentPublic source context ↗Public source context ↗Public source context ↗
2017-06-06-p-e-agenda-attachment-1-to-item-6-draft-alignment-amendments-part-1-pages-1-907-pdfRelated documentPublic source context ↗
About this file
- File size
- 18.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.