column 1 column 2
Specific Outcomes Acceptable solutions (if self-
Including amendments to 3 July 2017
assessableaccepted development subject to
The Noosa Plan
requirements)
Probable solutions (if code assessablecode
assessment)
e) involve construction of an on-site effluent
disposal system;
OR
S7.2 A site specific geo-technical report
prepared by a registered professional engineer
either—
a) certifies that the site is not at risk from
landslide emanating from the site or from
other land; or
b) identifies methods of stabilising all
buildings, accessways and use areas;
AND
S7.3 If the geo-technical report identifies
methods of stabilising buildings, accessways
and use areas, those methods are
implemented.
Water Supply Infrastructure
O8 Existing water supply infrastructure, S8.1 Buildings and structures are setback a
including pipeline corridor, is protected from minimum of 20m from a water supply pipeline
incompatible development to ensure the safety as shown on Overlay Map OM3.5.
and reliability of water supply network.
Gas Pipeline
O9 Adequate separation is provided between S9.1 No new buildings for the purpose of
the new building works and the gas pipeline Residential Uses (except for a Detached
shown on Overlay Maps OM3.5 or OM5.5; house or class 10 building), Education uses,
Wellbeing uses or Retail business uses are
within 200m of the gas pipeline shown on
Overlay Maps OM3.5 or OM5.5;
AND AND
S9.2 Any building works for the purpose of
storage of flammable, explosive or other
hazardous materials are not within 200m of the
gas pipeline shown on Overlay Maps OM3.5 or
OM5.5.
O10 Building works are constructed and S10.1 No solution provided (no requirement for
operated to avoid damaging or adversely self-assessableaccepted development
affecting the operation of the pipeline and the development).
supply of gas.
14.95 Built form
Height
O11 Buildings and other structures– S11.1 The maximum building height in storeys
a) are low rise and present a building height and metres is—
consistent with structures on adjoining and a) if in the Visitor Mixed Use Zone – 12m
surrounding land; (but not exceeding 3 storeys);
b) have a maximum building height of– b) if in the Noosa Heads Locality, Attached
i) for Visitor Mixed Use Zone - 3 Housing Zone –
storeys; a) Lot 4 on SP 100064 in Serenity Close
ii) if in the Noosa Heads Locality, Noosa Heads - 15m (but not
Attached Housing Zone— exceeding 4 storeys); or
Lot 4 on SP 100064 in Serenity b) otherwise - 12m (but not exceeding 3
103
Building Works Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB)Related documentPublic source context ↗Public source context ↗Public source context ↗
2017-06-06-p-e-agenda-attachment-1-to-item-6-draft-alignment-amendments-part-1-pages-1-907-pdfRelated documentPublic source context ↗
About this file
- File size
- 18.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.