                                                                    column 1                                              column 2
            Including amendments to 3 July 2017




                                                                Specific Outcomes                              Acceptable solutions (if self-
The Noosa Plan



                                                                                                      assessableaccepted development subject to
                                                                                                                       requirements)
                                                                                                       Probable solutions (if code assessablecode
                                                                                                                        assessment)
                                                  class 10 buildings are designed and sited to        a)   have a front boundary setback of at least
                                                  visually integrate with any associated dwelling          6m; and
                                                  unit and avoid dominating the street by—            b)   garage doors that face the street and are
                                                  a)    minimising the width of the garage or              visible from the road frontage have a
                                                        carport; and                                       maximum width of 6m within any one
                                                  b)    minimising projection of the garage or             plane, with additional garage doors
                                                        carport forward of the main face of the            setback an additional 1m from the
                                                        dwelling unit,                                     frontage to break up the width of the
                                                                                                           garage façade.
                                                  14.96    Effects of use
                                                  Lighting
                                                  O19 Lighting associated with the use or works       S19.1 A 1.5m landscaped buffer separates any
                                                  does not have an adverse impact upon the            private tennis court or other sports court from
                                                  amenity enjoyed by users of adjoining or nearby     side property boundaries;
                                                  premises nor do it cause unreasonable               AND
                                                  disturbance to local fauna..
                                                                                                      S19.2 Tennis courts or half courts are fenced
                                                                                                      with fencing of 3.6m in height for a full sized
                                                                                                      court or 2.4m in height for a half court;
                                                                                                      AND
                                                                                                      S19.3 Any lit tennis court or other sports court is
                                                                                                      located at least 60m from the external wall of an
                                                                                                      existing or approved residential dwelling on an
                                                                                                      adjacent or nearby lot (as measured from the
                                                                                                      centre line of the court);
                                                                                                      AND
                                                                                                      S19.4 For lighting–
                                                                                                      a)     the vertical illumination resulting from
                                                                                                             direct, reflected or other incidental lighting
                                                                                                             emanating from the site does not exceed
                                                                                                             8 lux when measured at any point 1.5m
                                                                                                             outside the boundary and at any level
                                                                                                             from ground level upward;
                                                                                                      b)     all flood lighting is hooded or baffled to
                                                                                                             direct lighting downward or is of a type
                                                                                                             that gives no upward component of light
                                                                                                             when mounted horizontally;
                                                                                                      c)     all flood lighting is setback a minimum of–
                                                                                                               i)    6m from the boundary to any
                                                                                                                     frontage; and
                                                                                                               ii) 2m to any other boundary; and
                                                                                                      d)     lighting structures are not more than 8m in
                                                                                                             height.
                                                  Environmental Protection
                                                  O20 The design, siting and construction of          S20.1 Where there is an existing building
                                                  buildings and structures minimise the clearing of   envelope on the lot that contains vegetation
                                                  vegetation and where there is an existing           protection measures, clearing of native
                                                  preliminary approval for the property that          vegetation and building works do not extend
                                                  contains vegetation protection measures, the        beyond the building envelope, except for the
                                                  proposal is consistent with those measures.         purposes of a driveway access;


                                                                                                     108
                                                                                            Building Works Code

Used in these records

About this file

File size
18.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB).pdf · 18.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.