column 1 column 2
Including amendments to 3 July 2017
Specific Outcomes Acceptable solutions (if self-
The Noosa Plan
assessableaccepted development subject to
requirements)
Probable solutions (if code assessablecode
assessment)
class 10 buildings are designed and sited to a) have a front boundary setback of at least
visually integrate with any associated dwelling 6m; and
unit and avoid dominating the street by— b) garage doors that face the street and are
a) minimising the width of the garage or visible from the road frontage have a
carport; and maximum width of 6m within any one
b) minimising projection of the garage or plane, with additional garage doors
carport forward of the main face of the setback an additional 1m from the
dwelling unit, frontage to break up the width of the
garage façade.
14.96 Effects of use
Lighting
O19 Lighting associated with the use or works S19.1 A 1.5m landscaped buffer separates any
does not have an adverse impact upon the private tennis court or other sports court from
amenity enjoyed by users of adjoining or nearby side property boundaries;
premises nor do it cause unreasonable AND
disturbance to local fauna..
S19.2 Tennis courts or half courts are fenced
with fencing of 3.6m in height for a full sized
court or 2.4m in height for a half court;
AND
S19.3 Any lit tennis court or other sports court is
located at least 60m from the external wall of an
existing or approved residential dwelling on an
adjacent or nearby lot (as measured from the
centre line of the court);
AND
S19.4 For lighting–
a) the vertical illumination resulting from
direct, reflected or other incidental lighting
emanating from the site does not exceed
8 lux when measured at any point 1.5m
outside the boundary and at any level
from ground level upward;
b) all flood lighting is hooded or baffled to
direct lighting downward or is of a type
that gives no upward component of light
when mounted horizontally;
c) all flood lighting is setback a minimum of–
i) 6m from the boundary to any
frontage; and
ii) 2m to any other boundary; and
d) lighting structures are not more than 8m in
height.
Environmental Protection
O20 The design, siting and construction of S20.1 Where there is an existing building
buildings and structures minimise the clearing of envelope on the lot that contains vegetation
vegetation and where there is an existing protection measures, clearing of native
preliminary approval for the property that vegetation and building works do not extend
contains vegetation protection measures, the beyond the building envelope, except for the
proposal is consistent with those measures. purposes of a driveway access;
108
Building Works Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB)Related documentPublic source context ↗Public source context ↗Public source context ↗
2017-06-06-p-e-agenda-attachment-1-to-item-6-draft-alignment-amendments-part-1-pages-1-907-pdfRelated documentPublic source context ↗