                  column 1                                            column 2
              Specific Outcomes                             Acceptable solutions (if self-




                                                                                                                       Including amendments to 3 July 2017
                                                     assessableaccepted development subject to




                                                                                                           The Noosa Plan
                                                                   requirements)
                                                     Probable solutions (if code assessablecode
                                                                    assessment)
                                                     OR

                                                     S20.2 Where there is no building envelope
                                                     existing on the lot, clearing of native vegetation,
                                                     other than for a driveway access does not
                                                     extend beyond—
                                                     a) 30m of a building or 10m of a structure on
                                                         lots greater than 10ha;
                                                     b) 10m of a building or structure on lots 10ha
                                                         or less but more than 0.3ha; or
                                                     c) 3m of a building or structure on lots 0.3ha or
                                                         less.
14.97    Self-contained units - building works
O21 Building works do not result in an increase      S21.1 A Detached House or Community
in the number of self-contained accommodation        residence or dwelling unit contains no more
units or dwelling units on a property.               than 1 kitchen and 1 laundry.
AND
O22 A Detached house accommodates 1                  S22.1 Studios, pavilions or other habitable
household only.                                      outbuildings have a maximum gross floor area
                                                            2
                                                     of 50m ;
                                                     AND
                                                     S22.2 No part of a Detached house or
                                                     Community residence containing habitable
                                                     rooms is more than 25m from another part of
                                                     the Detached house or Community
                                                     residence.
14.98    Protection of Extractive Resources
O23 Where located within proximity of                S23.1 Where located within an extractive
protected extractive resources, building works       resource area on Overlay Maps OM1.5—
for Residential Uses and Community Uses              OM9.5, residential or community buildings—
incorporate design, orientation, and construction    a) are located at least 200m from the
measures that mitigate the effects of noise,             Extractive Resource/Processing Area; and
dust, ground vibration, or air blast overpressure    b) achieve a minimum sound transmission
from the extractive industry.                            class rating of 30 for any windows or glass
                                                         doors on the wall closest to the Extractive
                                                         Resource/Processing Area.

Table 14-45 Removal buildings

14.99    Amenity
O24 The removal building does not have an            S24.1 Any part of the removal building that is
adverse impact on the amenity of the premises        affected by termite attack, borers, dry rot or
or surrounding premises.                             severe weathering is repaired or replaced using
                                                     new or sound second-hand materials;
 Advisory note                                       AND
 Council’s Environmental Health Section has          S24.2 Any part of the removal building that is
 guidelines for the transportation and disposal      damaged as a consequence of relocation is
                                                     repaired using new or sound second-hand
 of building materials containing asbestos.
                                                     materials;
 Locally, asbestos can only be disposed of at
                                                     AND
 Council’s landfill at Eumundi Road Noosaville.


                                                    109
                                           Building Works Code

Used in these records

About this file

File size
18.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB).pdf · 18.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.