RFI - Attachment C - Slope Stability Assessment and Geotechnical report · MCU20/0026
Project No. 1-22543 Page | 18 June, 2020 Ref: 1-22543, 2020-05-20, BR SSA VER 1 Sanya Holdings – Slope Stability Assessment and Geotechnical Report - Proposed Residence, 40 Park Crescent, Sunshine Beach The site being potentially subject to other factors resulting in foundation movement beyond the reactive soil movements resulting from moisture changes due to the normal site conditions described in AS 2870-2011 Clause 1.3.2 (i.e. Clause 1.3.3 abnormal moisture conditions). The site being potentially subject to landslip. 6.2.3 Further Comments Regarding Foundations Foundation Design As noted above this site has been classified as ‘P’, however, if the site was classified based on reactivity alone, under normal moisture conditions, a ground surface movement (ys) of <20mm (maximum) could be adopted, which relates to a Class ‘A/S’ (sand-rock/slightly reactive) site (considering the proposed development, existing subsurface profile as per boreholes records, and taking into account other relevant geotechnical data held by Soil Surveys Engineering). It should also be noted that the methodology adopted for determination of the site classification assumes the structure has performance requirements similar to domestic type construction. Development of Abnormal Soil Conditions It is recommended that design works for the proposed development take into account the long term effect of any design elements on the subsurface moisture conditions under and around the structure. These design works should consider aspects of the design that may contribute to the development of abnormal moisture conditions i.e.:- Site drainage Gardens and landscaping Future planting of trees and shrubs Services and repair of leaks The designer is directed to AS 2870-2011 Appendix B and Section 8.2.7 of this report which outlines measures that should be considered. 6.2.4 High Level Footings Where high level footings are adopted, our recommendation is that all perimeter footings, footings under isolated columns and strip footings below internal load bearing walls be founded at least 300mm below platform level and a minimum of 300mm into the natural sands. Table 6 outlines minimum allowable bearing capacities for high level foundations on the site. TABLE 6 ALLOWABLE BEARING CAPACITIES FOR HIGH LEVEL FOOTINGS Allowable Bearing Capacity (kPa) Material Strip Footing Pad Footing Fill Uncontrolled NR NR Sand Loose NR NR Compacted to 70% density index 100 125 Medium Dense 100 125 Note: NR - Not Recommended SOIL SURVEYS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment C - Slope Stability Assessment and Geotechnical report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.