Council archive · source document
RFI - Attachment C - Slope Stability Assessment and Geotechnical report · MCU20/0026
Project No. 1-22543 Page | 17 June, 2020 Ref: 1-22543, 2020-05-20, BR SSA VER 1 Sanya Holdings – Slope Stability Assessment and Geotechnical Report - Proposed Residence, 40 Park Crescent, Sunshine Beach Note: The surface silty sands will cause problems with trafficability/workability should this material be wet/become wet prior to or during construction. Given no structural filling is a currently proposed, no further specific earthworks recommendation will be provided. The author can be contacted if further information is required. 6.1.3 Batters It is understood that all cuts will be supported by temporary and later permanent retaining walls with no requirements currently for batters on the site. Should batter angles be required, please contact to author to discuss their use. 6.2 Building Foundations 6.2.1 General Given the subsurface profile encountered, the expected loads and likely excavation depths, a high level strip and pad footing system may be possible to be adopted for the proposed basement section (only) at the south western end of the development, provided all footings are founded into at least medium dense sand and the presence of loose sand is taken into account. Deep foundations would be required outside of the basement cut area to reach at least the medium dense sands (i.e. up to approx. 2.5m below existing down slope surface levels) and could also be adopted as an alternative foundation system across the entire site and/or for retention systems. 6.2.2 Site Classification as per AS 2870-2011 General A site classification, in accordance with AS 2870 'Residential Slabs and Footings' (it is recommended that the reader satisfy themselves that the use of AS 2870 is applicable for the proposed design) has been carried out with the following information:- Subsurface profile: Possible minor fill Natural sand soils Proposed earthworks: Cuts of up to approx. 4.0m to 5.0m with backfilling up to approx. 3.5m. Soil Moisture Model: A zone of moisture variation of 1.8m A crack zone of 0.9m pF = 1.2 Site Classification According to AS 2870-2011, the site has been designated Class 'P' due to:- The potential presence of uncontrolled fill in excess of 0.4m in depth as defined in AS 2870-2011 Clause 2.5.3; SOIL SURVEYS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment C - Slope Stability Assessment and Geotechnical report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.