Council archive · source document
Attachment 6 - Acoustic Report (Updated) 20.08.2020 · OPW20/0145
Table 5 – Predicted Shopping Centre Noise Impacts at the Proposed Residential Lots
Predicted Incident Noise Level Acoustic
Receiver1 Time
at Facade dB(A) Treatment
Internal
Compact. Mech.
Required
Noise Level
LA12 Plant3 to Achieve
Loading Criteria
LAeq Indoor
Dock, LA1 dB(A)
Noise
Limit4
Day 52 28 52 45 LA1,adj,1hr
Lot 17 Ground Evening N/A 35 LAeq,adj,1hr
Type A
level 41 40 LA1,adj,1hr
Night
30 LAeq,adj,1hr
Day 57 28 56 45 LA1,adj,1hr Type A
Evening N/A 35 LAeq,adj,1hr
Lot 17 Level 1
45 40 LA1,adj,1hr
Night
30 LAeq,adj,1hr
Day 60 29 57 45 LA1,adj,1hr Type A
Evening N/A 35 LAeq,adj,1hr
Lot 17 Level 2
48 40 LA1,adj,1hr
Night
30 LAeq,adj,1hr
Day 46 37 51 45 LA1,adj,1hr Acoustic
35 LAeq,adj,1hr Seals to
Evening N/A
Lot 18 Ground windows,
level 43 Non glazed
40 LA1,adj,1hr
Night wall to Type
30 LAeq,adj,1hr
A
Day 47 37 57 45 LA1,adj,1hr
Evening N/A 35 LAeq,adj,1hr
Lot 18 Level 1 Type A
45 40 LA1,adj,1hr
Night
30 LAeq,adj,1hr
Day 47 41 57 45 LA1,adj,1hr
Evening N/A 35 LAeq,adj,1hr
Lot 18 Level 2 Type A
46 40 LA1,adj,1hr
Night
30 LAeq,adj,1hr
Day 52 55 53 45 LA1,adj,1hr Type A
Lot 19 Ground Evening N/A 35 LAeq,adj,1hr
level
39 40 LA1,adj,1hr
Night
30 LAeq,adj,1hr
Lot 19 Level 1 Day 61 63 56 45 LA1,adj,1hr Type B
I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx 23
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 6 - Acoustic Report (Updated) 20.08.2020.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.