Bushfire Hazard Assessment & Management Plan v1 - 60 Glenridge Drive COOROIBAH
Original PDF page 19, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment & Management Plan v1 NCES REF: J001001 Lot 47 on RP860577 – 60 Glenridge Drive, Cooroibah society will not accept this risk and measures are to be put in place to reduce risks to at least a tolerable level. Assessment Benchmark 4 of the SPP Bushfire 2019 references radiant heat flux exposure of <29kW/m² on any part of the building as generating an Acceptable to Tolerable level of risk. AS/NZS ISO 31000:2018 defines ‘Likelihood’ as the chance that something might happen. Likelihood can be defined, determined, or measured objectively or subjectively and can be expressed either qualitatively or quantitatively (using mathematics ). The following ‘likelihood’ categories for the probability of the assessed bushfire attack mechanisms impacting the assessment area have been adopted within this assessment: • Likely - Will probably occur • Unlikely - Could occur but doubtful The determination of whether a bushfire event is likely or unlikely to occur (i.e., impact the site) has been based on the relative position of hazardous vegetation to the site. Hazardous vegetation located upwind of the site under typical south-east Queensland (SEQ) seasonal fire winds from the north to north-west to west to south-west are deemed to be exposed to a ‘likely’ probability of impact. Hazardous vegetation located downwind of the site under typical SEQ seasonal fire winds are deemed to be exposed to an ‘unlikely’ probability of impact. 4.2 Risk from Identified Hazardous Vegetation The Plan of Development depicts building envelopes within the proposed Lots which will be primarily flanked by hazardous on all sides, precluding Lots 1 and 2. The likelihood of a fire approaching from the northwest, west, and southwest is considered likely, given dominant regional fire weather winds are derived from the north-west to south-west. The degree of separation offered to the adjoining vegetation is the primary driver of the assigned level of risk and was determined with consideration to the Flamesol modelling output presented in Section 3.3. In the absence of an appropriate separation buffer to the adjacent vegetation, and implementation of relevant AS3959-2018 construction standards, the future dwellings on the site could be exposed to direct flame, severe radiant heat and ember attack during the modelled bushfire conditions resulting in total structure loss. The Plan of Development depicts a minimum 25m setback between the proposed building envelopes and the onsite revegetation works and/or off-site hazardous vegetation (VHC 22.1 forest). A minimum of 20.1m is the minimum separation required to ensure the proposed building envelopes on the Lots 1-8 are exposed to <29kW/m² radiant heat flux as per the Flamesol modelling presented herein. The extent of proposed separation therefore facilitates an acceptable risk of radiant heat impact thereby satisfying Assessment Benchmark 4 of the SPP Bushfire 2019. © 2021 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.