Original source · versioned page text
Bushfire Hazard Assessment & Management Plan v1 - 60 Glenridge Drive COOROIBAH
Original PDF page 30, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment & Management Plan v1 NCES REF: J001001 Lot 47 on RP860577 – 60 Glenridge Drive, Cooroibah 7.2 State Planning Policy – Natural Hazards, Risk and Resilience The Department of State Development, Manufacturing, Infrastructure and Planning’s State Planning Policy – State interest guidance material – Natural hazards, risk and resilience – Bushfire (December 2019) contains the development assessment benchmarks for natural hazards, risk and resilience - bushfire. The SPP assessment benchmarks prevail over those prescribed in the Noosa Plan Natural Hazards Overlay Code where they involve the same design elements. An assessment of the proposed development’s compliance with each of the assessment benchmarks has been provided below. Assessment Benchmark 4 To ensure emergency services can respond effectively, development is located within a reticulated water supply area or includes a dedicated static water supply that is available solely for fire-fighting purposes and can be accessed by fire-fighting vehicles. Reticulated water supply is not available to the site hence a dedicated static water supply of 10,000L for each future dwelling is recommended as per the SPP Bushfire 2019 water supply guidance material recommendations. Where reconfiguring a lot creating lots of greater than 2000 square metres To ensure emergency access and operational space for firefighters, include a development footprint plan that is separated from the closest edge of the adjacent mapped medium, high or very high potential bushfire intensity area by a distance that achieves a radiant heat flux level of 29 kilowatt per square metre or less. To facilitate safe evacuation during a bushfire event, include a development footprint plan that is located within 60 metres of the street frontage and sited to enable a route between the development footprint plan and the street frontage with a gradient that does not exceed of 12.5 per cent. All of the proposed BLE’s are provided with enough separation to achieve <29 kW/m² radiant heat flux hence satisfying the Assessment Benchmark 4 <29 kW/m² criteria. All of the proposed BLE’s will be located <60m from either Glenridge Drive or the proposed new internal road and accessed via driveways with a gradient of well less than 12.5%, precluding the BLE on Lot 3 which requires an approximate 90m traverse from the proposed cul de sac head. The sharded driveway to Lot 3 traverses low threat conditions created by the future dwellings and associated APZ’s on Lots 4, 6 and 7 and therefore is not expected to be exposed to risk of restricted egress and access during a bushfire emergency on the site. Where reconfiguring a lot creating additional lots for the purpose of residential development and a reticulated water supply is not provided (fire trails). To ensure safe access and egress and operational space for rural fire-fighting vehicles, a fire trail and working area is provided that separates the new residential lot or development footprint plans from adjacent mapped medium, high or very high potential bushfire intensity and is designed and constructed in accordance with the design parameters in Table 4. An SPP compliant fire break trail has been recommended. Assessment Benchmark 5 Where reconfiguring a lot. Subdivision design avoids locating lots (or for lots greater than 2000 square metres, avoids locating the development footprint plan) that are within bushfire prone areas and on ridgelines, saddles and crests where slopes exceed 15 per cent. All of the proposed Lots are >2000m² and the whole site is positioned on slopes of <15%. Assessment Benchmark 7 Where a requirement for an asset protection zone (or similar) exists Landscaping treatments comprise only low threat vegetation, including grassland managed in a minimal fuel condition, maintained lawns, golf courses, maintained public reserves and parklands, © 2021 29
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.