                                    INSTALLATION

Trolley Installation Instructions

1. Attach the mounting brackets to the track.
2. Mark a horizontal line 6” down from the ceiling of the vault structure on the two long walls.
3. Each track is split in sections. The length and number of sections vary depending on the vault. It is generally
   better to start installing longer track sections first. Hold a section in place and align the top of the brackets with
   the horizontal line on the wall. Mark the center of the hole in each bracket and remove the track.
4. Using a hammer drill and ¼” bit, drill a hole approximately 3” deep at each mark.
5. Hold the track back in place and realign the brackets with the holes. Place a plastic spacer block behind each
   bracket and using the supplied ¼” x 3¼” anchor bolts mount the track in place. Only install one section of track
   at this stage.
6. Repeat this procedure on the opposite wall of the vault directly across from the first section.
7. Bolt the 4 trolleys to the aluminum I-beam as shown in the attached diagram. Make sure that the wheels for
   each trolley are mounted an equal distance from the top of the I-beam.
8. Lift the I-beam in to place and insert the trolleys in to the track.
9. Using the supplied couplers, install the second sections of track via the same procedure. Continue until the track
   runs the length of the vault or as designed.




                                                                  19
Log in to download the original file

Stormwater Management Plan - Rev 1.pdf · 12.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.