       Performance outcomes                                 Acceptable outcomes                                      Response
2. the long term physical integrity of
   waterways, wetland and areas of native
   vegetation.

Water Supply for Fire Fighting Purposes
PO3                                               AO3.1                                             R3.1
Development provides an adequate water            Premises are connected to the reticulated
supply for fire fighting purpose which is         water supply.                                     The subject site has access to a reticulated
reliable, safely located and freely accessible.                                                     water supply/is in a water service area.
                                                  Editor's note—For reconfiguring a lot, water
                                                  supply needs to provide for a minimum flow and
                                                  pressure of 10 litres a second at 200kPa at all
                                                  times for fire fighting purposes.

                                                  OR

                                                  AO3.2
                                                  Where there is no available reticulated water
                                                  supply, the premises has:

                                                  1. an accessible dam, swimming pool or
                                                     water tank available for fire fighting
                                                     purposes with an onsite water volume of
                                                     not less than 5,000 litres; and
                                                  2. a water supply outlet pipe 50 millimetres in
                                                     diameter fitted with a standard fire brigade
                                                     fitting connected to the water supply (other
                                                     than where the water supply is in a
                                                     swimming pool or dam).


RFA17-040Bushfire Hazard Assessment & Mitigation Plan | 61 Noosa Springs Dr. Noosa Heads                                               30 April 2022

                                                          Rob Friend & Associates Pty Ltd

Log in to download the original (Attachment 4 - Response to Further Advice Rob Friend and Associates.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.