Original source · versioned page text
Appendix D - Medium Density Residentail Zone Code
Appendix D – Medium Density Residential Zone Code Development Permit for Material Change of Use of Premises for a Multiple Dwelling of 4 Units and Operational Works over Lots 3 and 4 on RP72986 located at 30 & 32 James Street Noosaville Column 1 Column 2 Column 3 Performance Outcomes Acceptable Outcomes Compliance 1A and figure AP3-1C AO20.4 Complies Planter boxes, screens, pergolas, landscaping and architectural design of balconies are used to screen the ground floor private open space of dwellings from separate upper level dwellings. Editor's note—refer to figure AP3-1A AO20.5 Complies – aluminium screens proposed. Permanently fixed external screening devices complement the building's external materials and finishes and may incorporate solid translucent screens, shutters, perforated panels or trellises which have a maximum of 50% openings. Editor's note—refer to figure AP3-1B PO21 AO21.1 Mechanical plant, vehicle manoeuvring, utilities Communal outdoor recreational facilities Complies – private individual pools provide for and communal outdoor recreation uses: including swimming pools, spas and sports each unit. a. do not have an adverse effect on the courts are: amenity enjoyed by users of adjacent or nearby premises through emission of a) setback at least 12 metres from the noise, light, fumes or smoke; and boundary of land in a residential b. do not cause unreasonable disturbance zone and screened by a 5 to local fauna through light or smoke metre wide buffer densely planted emissions. with trees and shrubs including species from 1 metre to 8 metres in height; or b) located internally to the arrangement of buildings on the site; and c) not used between the hours of 9:00pm and 6:30am the following day. AO21.2 Not applicable – not a lit court For a lit sports court: a) the court is located at least 60 metres from the external wall of an existing or approved dwelling on adjoining or nearby premises (as measured from the centre line of the court); and b) the vertical illumination resulting from direct, reflected or other incidental light emanating from the site does not exceed 8 lux when measured at any point 1.5 metres outside the boundary and at any level from ground level upward; and c) any floodlighting is restricted to the types that give no upward component of light were mounted horizontally (i.e. a full cut off luminaire). Page 9
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.