Development Application part 2 of 2 plans - MCU13/0080
Plans and drawings: the text below has words only, no drawings.
Very large file (51.3 MB): may take a few minutes to open.
I’
3:May2013
18 Sunsee r Crose the certifier
combined- 0.5:1;
b) Precinct 83- 0.8;
c) Precinct E1- 0.6;
d) Precinct E2- 0.6;
e) Precinct E3- 0.6;
f) Precinct E4- 0.6;
g) Precinct E5- 0.6
h) Precinct E6- 0.6;
i) Precinct E7- 0.6;
j) Precinct RES- 0.6; and
k) Precinct REC/MU- 0.1.
017Buildings and other works 517.1 For new buildings or 517.1- The proposal complies
are designed and sited to- structures or additions of more with the designated minimum
a) provide flood free access to than 50m2 gross floor area
floor level of 2.6m AHD as
premises and .flood free to an existing building or
specified in the submitted
habitable areas; structure, floor levels for
habitable rooms are not less Flood Search provided by
b) allow only minor, short term
and infrequent flooding of non- than the specified minimum floor Sunshine Coast Council.
habitable areas; levels;
c) ensure carparking areas can AND
Proposal complies
be adequately drained; 517.2 Where Council
d) ensure drainage does not infrastructure is available-
517.2 -
The stormwater is
adversely impact upon other a) any drainage (including
premises; and buildings and yards) flows to capable of being directed to
e) ensure filling or excavation that infrastructure; and the lawful point of discharge
does not adversely impact upon b) the infrastructure has the on the street. Relevant
other premises by- capacity to accept any additional conditions of approval can be
i. causing ponding on the site or loading; included in the development
nearby land; AND
ii. increasing flooding, which 517.3 For Residential Uses- permit.
adversely affects the safety or a) where slab on ground
use of any land upstream and construction is used, filling does Proposal will comply
downstream; and not extend more than
iii. adversely affecting the flow 1 m beyond the building footprint 517.3 -
The lot is relatively flat
of water in any overland flow and access to car parking areas,
minimal fill will be required to
path. measured from the outer walls
raise the level of the lot to
of the building; or b) the design
consists of a suspended floor flood immunity for the
construction; habitable rooms.
AND
517.4 Car parking and
Proposal complies
maneovering areas are
constructed at a level that
permits the parking area to drain
from the site by gravity
means, without the need for
mechanical pumping;
AND
517.5 Basements for residential
uses have flood immunity above
the Q 100 where alternative
means to mechanical pumping
are used to achieve such
immunity; or
517.6 Basements for non-
18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 of 2 plans - MCU13/0080Related documentApplication case desk ↗
About this file
- File size
- 51.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.