Council archive · source document
Development Application part 2 of 2 plans - MCU13/0080
Plans and drawings: the text below has words only, no drawings.
Very large file (51.3 MB): may take a few minutes to open.
~
3’May2013
18Sunseef<gr Crose
the certifier
Watercourses
027The environmental, No solution provided Not applicable.
economic, amenity and
transportation values of the
Not located adjacent to the
Noosa River system are
river system.
protected.
Schedule 1 The Noosa Plan
-
Minimum Boundary Setbacks
Table 1.1 - Minimum Setbacks for Zones
Attached Housing Zone
Table 1.3 Exceptions for specific uses
-
Multiple housing Type 4 Conventional
-
Compliance
Frontage-6m for 2 storey buildings or The setback to the 2 storey building is a
for 3 storey or 4 storey buildings-6m for the first
minimum of 6 metres from the front boundary.
2 storeys and 10m for any storey thereafter
Side boundaries-half the building height in The roof form of the development is generally
metres calculated at that same point provided skillion. The maximum height is approximately
that on any gable roof the calculation shall be 6.27m from NGL. The point of the roof where
measured to half the height of the gable the side setback is closest is approximately
S.2S0m, requiring a setback of approximately
Rear boundary-6m for 2 storey buildings or for
2.62Sm.
3 storey or 4 storey buildings-6m for the first 2
storeys and 8m for any storey thereafter
Where there are 2 or more buildings proposed to The minimum setback on the eastern side
be developed on one site, the distance between boundary is 770mm.Therefore the setbacks do
any part of a building and any part of another not comply with the probable solution.
building on the same site shall not be less than
However, the proposal is considered to comply
1.5m plus O.5m for each storey of the building
with the Specific Outcomes of the applicable
with the greatest number of storeys
codes (see element 09 of the Noosaville
Locality Code above).
The rear setback to the rear 2 storey unit has
been reduced to from 6m to 5 metres.
However, the proposal is considered to comply
with the Specific Outcomes of the of the
applicable codes (see element 09 of the
Noosaville L cality Plan above).
22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 of 2 plans - MCU13/0080Related documentApplication case desk ↗
About this file
- File size
- 51.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.