3’May2013
18 Sunsee   I’C[ose                                                                the certifier
Division 6   -
                  Residential Uses Code




Specific Outcomes                  Probable Solutions                   Compliance
14.46 Effects of use

Electricity supply                 S1.1 No solution provided            The proposed development is
infrastructure                     S2.1 Development for uses            not located near an electricity
01 The development does not        adjacent to or within 50m of an      substation or easement.
adversely impact on existing or    existing electricity substation
future electricity supply          incorporates noise attenuation
                                                                        Relevant conditions of
infrastructure;                    measures to mitigate noise

AND                                impacts;                             approval can be included in the
02All uses and works maintain      AND                                  development permit.
an   adequate safe distance from   S2.2 Buildings and structures
electrical infrastructure          (including swimming pools,
                                                                        Proposal
including substations, overhead    sheds, tennis courts or
powerlines, power poles and        outbuildings) are not
transformers.                      constructed under overhead
                                   electricity transmission lines, or
                                   within electricity easements;
                                   AND
                                   S2.3 A minimum separation
                                   distance is maintained from the
                                   electricity transmission line to
                                   the closest boundary of
                                   habitable buildings and child
                                   activity areas, as follows-
                                   a) 20m for transmission lines up
                                   to 132kV;
                                   b) 30m for transmission lines
                                   between 133kV and 275kV; and
                                   c) 40m for transmission lines
                                   greater than 275kV.

Hot Water Systems14                S3.1 All hot water systems           Relevant conditions of
03 Hot water systems are           installed are-
                                                                        approval can be included in the
installed and operated to          a) solar systems; or
                                                                        development permit.
support the efficient use of       b) electric heat pump systems;
natural resources and minimise     or
                                                                        The proposal will comply
consequent pollution such as       c) natural gas or LPG systems;
greenhouse gas emissions.          or

                                   d) any combination of a), b) or
                                   c).

Water supply and                   S4.1 & S5.1 For a Class 1            Not applicable.
conservation                       building15 other than
04 On-site water storage is        a Detached      house or Multiple
designed and operated to           Housing Type
support the efficient use of       1, outside a reticulated water
water;                             service area, a rainwater tank is
AND                                to be installed with the following
05 On-site water storage is        minimum storage capacities-
adequate for occupants every       a) Where no more than 3
day use and fire fighting          bedrooms    -




purposes.                          45,000 litres; or

                                                       23

Used in these records

About this file

File size
51.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application part 2 of 2 plans - MCU13_0080.pdf · 51.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.