Development Application part 2 of 2 plans - MCU13/0080

of 68

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Very large file (51.3 MB): may take a few minutes to open.

Log in to see the plans as drawn
                                                                                 I’-
3’May2013
18Sunsee/{gr CCose                                                               the certifier
                                                                        the residents by allowing
                                                                        natural surveillance.


                                                                        The proposal is therefore
                                                                        considered to comply with 07.


Emergency access                   No solution provided                 Emergency vehicle access is
08 For Multiple housing Type                                            available along the proposed
3, 4 & 5, site design and layout
                                                                        driveway and in the visitor car
ensures efficient access and
                                                                        bays.
egress for emergency vehicles.


                                                                        Proposal complies

Basement drainage                  S9.1 Enclosed car parking and        Not applicable.
09 Buildings and access works      manoeuvring areas are
are   designed and sited to        constructed at a level that
                                                                        No basements proposed.
protect persons and property in    permits the parking area to
the event of a flood and power     drain from the site by gravity
failure                            means, without the need for
                                   mechanical pumping


Separation of incompatible         S10.1 Bedroom windows are at         There are no bedroom
uses                               least 3m away from shared            windows proposed within 3
010 Development is designed        driveways or car parking areas       metres of the of the shared
to minimise noise carrying         of adjacent dwelling units or
between dwelling units or          accommodation units.                 driveway.
accommodation units by
locating noise sensitive                                                Proposal complies
spaces such as bedrooms away
from noise generating areas of
the development, such as
carparking areas or mechanic
plant and equipment or
recreational facilities.


Mechanical plant &                 S11.1 Mechanical plant and           There are no pools or spas
equipment                          equipment, including pool and        proposed. Relevant conditions
011 Mechanical plant and           spa pumps, pool heaters,             of approval can be included in
equipment associated with          air-conditioning units and
                                                                        the development permit.
Residential Uses are designed      refrigeration units are-
and located so as not have an      a) where located at ground
adverse impact on the visual       level, screened by fencing 1.5m      Proposal will comply
amenity of the site or             in height or dense vegetation of
surrounding areas.                 at least 1.5m in width
                                   incorporating grouped trees and
                                   shrubs with maximum
                                   separation distance of
                                   1 m measured from the centre of
                                   the plant; and


                                   b) for Multiple housing Type 2,
                                   3 & 4 are visually integrated into
                                   the line and_Qlane of the



                                                    25

Used in these records

About this file

File size
51.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application part 2 of 2 plans - MCU13_0080.pdf · 51.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.