Skip to the record
NoosaWatch™: The source of truth.

Original source · versioned page text

Appendix I - Local Planning response

of 69

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Specific outcomes                                             Probable solutions                                Response

 j) Precinct RES- 0.6; and
 Precinct REC/MU- 0.1.


 Flooding and drainage70                                       S17.1 For new buildings or structures or          Complies
 O17 Buildings and other works are designed and sited to—      additions of more than 50m2 gross floor area      The difference in footprint area of the former boat shed
                                                               to an existing building or structure, floor       compared to the new shed is approximately 47m2. The impact
 a)    provide flood free access to premises and flood free
                                                               levels for habitable rooms are not less than      of this structure on flood storage is negligible.
       habitable areas;
                                                               the specified minimum floor levels;
 b)    allow only minor, short term and infrequent
       flooding of non-habitable areas;                        AND                                               Stormwater runoff from the site will be discharged directly into
                                                               S17.2 Where Council infrastructure is             the river, with the balance directed through the stormwater
 c)    ensure carparking areas can be adequately
                                                               available—                                        network within the caravan park and then discharged to the
       drained;
 d)    ensure drainage does not adversely impact upon           a)     any drainage (including buildings and     river.
       other premises; and                                             yards) flows to that infrastructure;
                                                                       and
 e)    ensure filling or excavation does not adversely
                                                                b)     the infrastructure has the capacity to
       impact upon other premises by—
                                                                       accept any additional loading;
        i.     causing ponding on the site or nearby
               land;                                            AND
                                                               S17.3 For Residential Uses—
        ii.    increasing flooding, which adversely
               affects the safety or use of any land           a) where slab on ground construction is
               upstream and downstream; and                         used, filling does not extend more than
                                                                    1m beyond the building footprint and
        iii.   adversely affecting the flow of water in
                                                                    access to car parking areas, measured
               any overland flow path.
                                                                    from the outer walls of the building ; or
                                                               b) the design consists of a suspended floor
                                                                    construction;
                                                               AND
                                                               S17.4 Car parking and maneuvering areas are
                                                               constructed at a level that permits the
                                                               parking area to drain from the site by gravity
                                                               means, without the need for mechanical
                                                               pumping; AND
                                                               S17.5 Basements for residential uses have
                                                               flood immunity above the 1%AEP defined
                                                               flood event where alternative means to
                                                               mechanical pumping are used to achieve


                                                                                                                                                                P a g e |8
Log in to download the original file

Appendix I - Local Planning response.pdf · 522 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.