37.   A suitably qualified Registered Professional Engineer shall prepare engineering drawings and
      specifications for all engineering works that will become Council infrastructure. In this regard a
      DXF/DWG file on GDA94 zone 56 grid of the proposed cadastre layout is to be submitted.
38.   Digital detailed design drawings and calculations shall be submitted in respect of roadworks
      and stormwater drainage works. To avoid conflict with underground pipes or services, all
      existing and proposed services required by the development shall be shown on the plans.
39.   To facilitate production of As Constructed drawings it is suggested that all design drawings are
      submitted in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the
      use of ADAC are available at www.adac.com.au).
40.   Any damage caused to any public utility during the course of construction shall be repaired to
      Council’s standards and at no cost to Council.
41.   Any alteration of any public utility or other facilities necessitated by the development of the
      land or associated construction works external to the site shall be at no cost to Council.
42.   The transportation of all materials to and from the site shall be undertaken in a manner such
      that no particle matter escapes onto a public road. All vehicles carrying materials either to or
      from the site shall be covered to prevent materials including dust being windblown from the
      vehicle.
43.   As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer
      for design intent, and a Licensed Surveyor shall certify the cadastre and the location, level and
      type of all services and structures. All of which shall be submitted to Council for checking and
      for Council’s records.
      The data must fully detail levels for all engineering works including but not limited to drainage
      structures, finished ground levels and pavement surface levels. The data shall be submitted in
      the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC
      are available at www.adac.com.au).
      Approval of works shall not be granted until all As Constructed information has been supplied
      and accepted by Council.
Environmental Health
44.   The developer must provide waste storage and disposal facilities in accordance with Planning
      Scheme Policy No. 9 “Waste Management Multi-Dwellings and Commercial and Industrial
      Premises”, including an external imperviously paved area correctly sized for all refuse and
      recycling containers and suitably screened from public places and neighbouring properties. A
      bin wash area is required with a cold-water tap, hose and drain outlet connected to sewer. The
      drain outlet is to be designed to prevent storm water entry to the sewerage system and this
      can be achieved with a nib wall 50mm high and up to 700mm x 700mm wide (max 0.5m²), or
      alternatively the waste area can be roofed, or any other design approved by Council.
45.   All bin wash areas in excess of 700mm Square are to be roofed and the floor is to fall to a
      bucket trap with the waste pre-treated by a grease arrestor prior to discharge to the sewer.
      The appropriate backflow prevention devices are to be installed at the bin wash area. Bunding
      set above 75mm is required to exclude excessive rain-water entering these areas.
46.   A Trade Waste Application must be submitted prior to the issue of a Development Permit for
      Building Works.
47.   Full truck access is to be provided to each grease arrestor and/or pre-treatment device for
      cleaning and servicing. Where access is restricted, a pump out line is required.
48.   A completed Trade Waste application together with an applicable fee and two (2) sets of
      professionally drawn plans showing the Trade Waste requirements in accordance with the
      Noosa Trade Waste Policy are to be submitted to Council.


                                                                                      Page 8 of 19

Used in these records

About this file

File size
366 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Permissible Change Decision Notice Approval or App in Part - 010.2006.00001168.002 [As Published].pdf · 366 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.