NOOSA COUNCIL IDAS Development Application Decision Notice                                                    4 of 8


10.   The applicant must ensure that all landscaping treatment does not unduly restrict/prevent access to
      service meters within the site.

11.   All works are to be in compliance with the relevant conditions of Development Permit No. 2005/2291.

12.   This Development Permit lapses if the development has not happened by 8 August 2009, unless
      application to extend the currency is approved by Council.

Environmental Health

13.   The applicant shall comply with Condition 51 of Development Permit No. 2005/2291. As such, waste
      bricks and concrete are to be segregated separately from other waste being transported to the Noosaville
      Waste Transfer Station.

Land Development

14.   The development shall be carried out generally in accordance with drawings Nos.

      F06-012 2 of 21 Rev G        dated 6 July 2007     by F3 Design and Architecture

      F06-012 3 of 21 Rev G        dated 6 July 2007     by F3 Design and Architecture

      F06-012 4 of 21 Rev G        dated 6 July 2007     by F3 Design and Architecture

      F06-012 2 of 21 Rev E        dated 28 May 2007 by F3 Design and Architecture

      0127 – R01 Rev A             dated 8 June 2006     by Contour Consulting Engineers

      or as modified herein.

15.   The driveway width within the Ventura Street road reserve between the kerb and channel and the property
      boundary shall be a maximum width of 4.5 metres.

16.   Roof and surface runoff connection to Council’s drainage system shall be generally as shown on drawing
      No. 0127 – R01 Rev A dated 8 June 2006 by Contour Consulting Engineers. Roof runoff shall be directed
      to the proposed rainwater tanks and the overflow from the tanks shall be directed to the stormwater
      disposal system. In this regard a revised drainage plan signed by the Design Engineer indicating the
      abovementioned changes shall be submitted to Council for approval prior to the pre-start meeting.

17.   A bikeway/footpath 1.5 metres wide shall be constructed across the full frontage of the development. The
      footpath shall have a slip resistant surface. The alignment, of which, shall be determined on site with
      Council’s Construction Technical Officer. The expansion joints in any bikeway/footpath shall be “sawcut”
      not trowel jointed.

18.   Install suitable root barrier where proposed trees are adjacent to paths, pavement etc in accordance with
      Council’s Planning Scheme Policy PSP03 Landscaping Plants and Guidelines.

19.   Suitable sediment control devices ("in pit” pollution control devices) shall be temporarily installed into the
      first existing external downstream stormwater structure.
      These devices are to be checked and cleaned on a regular basis and specifically after each rain event.
      These devices are to remain in place during the civil works and construction phases of the development.
      The location and type of device to be installed shall be established at the “pre start” meeting with
      Council’s Construction Technical Officer and shall be installed prior to the commencement of any works.
20.   Council’s Construction Technical Officer - (ph 0410 512 505), shall be given seven (7) days’ notice of
      intention to commence works to arrange a “pre start” meeting regarding the civil works.

21.   The principal contractor must have all the appropriate insurance and public liability documentation to carry
      out the works. The principal contractor is also responsible to ensure that any sub contractors also have
      the appropriate insurance and public liability documentation.

22.   Prior to the “pre start” meeting, the principal contractor must be provided with a copy of Council’s
      signed approved drawings and conditions by the applicant.




AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@5404378a\@[email protected]

Used in these records

About this file

File size
38 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

0015A7CC.001.pdf · 38 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.