Council archive · source document
Attachment A - Code Assessment [As Published] · 132010.871
Specific Outcomes Probable solutions Proposal
S2.2 Buildings and structures (including Complies
swimming pools, sheds, tennis courts or No buildings or pools will be constructed
outbuildings) are not constructed under under overhead electricity lines or within
overhead electricity transmission lines, easements.
or within electricity easements;
AND
S2.3 A minimum separation distance is Complies
maintained from the electricity Minimum separation distances are
transmission line to the closest boundary achieved.
of habitable buildings and child activity
areas, as follows—
a) 20m for transmission lines up to
132kV;
b) 30m for transmission lines between
133kV and 275kV; and
c) 40m for transmission lines greater
than 275kV.
Hot Water Systems Complies
O3 Hot water systems are installed and S3.1 All hot water systems installed An appropriate hot water system will be
operated to support the efficient use of are— installed.
natural resources and minimise a) solar systems; or
consequent pollution such as b) electric heat pump systems; or
greenhouse gas emissions. c) natural gas or LPG systems; or
d) any combination of a), b) or c).
Water supply and conservation
O4 On-site water storage is designed S4.1 & S5.1 For a Class 1 building Not Applicable
and operated to support the efficient other than a Detached house or The site is within a reticulated water
use of water; Multiple Housing Type 1, outside a area.
reticulated water service area, a
AND rainwater tank is to be installed with the
following minimum storage capacities—
O5 On-site water storage is adequate a) Where no more than 3 bedrooms –
for occupants every day use and fire 45,000 litres; or
fighting purposes. b) Where more than 3 bedrooms –
60,000 litres;
AND
c) There is to be on the lot a dam,
swimming pool or water tank accessible
for use by the fire brigade that contains
at least 5,000 litres of water.
Advisory note
The 5,000 litres required can be
included within the water required in
S4.2 or S5.1 providing it is accessible for
the purpose of fire fighting at all times
and not used for other domestic
purposes.
Erosion and sediment control
O6 Development does not cause erosion No solution provided. Complies
or result in transport of sediments off- Development will not cause erosion or
site. Advisory Note result in the transport of sediments off-
Persons undertaking development, site. This can be addressed in further
including building work, are required detail as part of a subsequent
under the Environmental Protection operational works application.
(Water) Policy 1997 (EPP) to ensure that
sediment and other material including
building waste, sawdust, concrete,
cement or paint are not deposited or
released into a roadside gutter,
stormwater drain or waterway, or into a
place where it could reasonably be
expected to move or be washed into a
See the original