O30     Buildings give the physical        S30.1 No solution provided                  Complies
appearance of being one Detached                                                       The subject site which achieves road
house, or a series of small separate                                                   frontage to two streets assists the
structures having the appearance of                                                    proposed duplex to appear as a series of
Detached houses;                                                                       small separate structures having the
                                                                                       appearance of detached houses.
AND

O31    Buildings and structures are        S31.1 No solution provided                  Not Applicable
designed to address any waterfront                                                     The site does not have a waterfront
aspect and to contribute positively to                                                 aspect.
the waterfront character.
Garages and carports
O32 Garages and carports are designed      S32.1 Garages and carports—                 Complies
and sited to visually integrate with the   a) have a front boundary setback of at      The garages exceeds the minimum 6m
building and avoid dominating the          least 6m; and                               frontage setback. Both garages are
street.                                    b) adopt a roof form and building style     integrated into the proposed buildings.
                                           similar to that of the building; and        Only one of the garages faces a street
                                           c) present a minimum width to the           frontage and is no more than 6m wide.
                                           streetscape (the total width of garage
                                           doors is no more than 6m or 50% of the
                                           frontage width, whichever is the lesser,
                                           where the structure faces the street); or
                                           d) that are visible from, but do not face
                                           the street, include windows or other
                                           articulation and have a 6m landscaped
                                           buffer between the structure and the
                                           road frontage.


Comment: The proposed Multiple Housing – Type 2 (Duplex) development achieves compliance with
the Specific Outcomes and Probable Solutions of the Noosa Heads Locality Code, with the exception of
specific outcome O27. Where non-compliant with a Probable Solution a suitable alternative solution is
provided in accordance with the applicable Specific Outcome. Sufficient planning justification has been
provided to overcome any conflict with specific outcome O27.



RESIDENTIAL USES CODE
Table 14-24 — For All Residential Uses
Specific Outcomes                          Probable solutions                          Proposal
14.46 Effects of use
Electricity supply infrastructure
O1 The development does not adversely      S1.1 No solution provided.                  Complies
impact on existing or future electricity                                               The proposed development for a
supply infrastructure;                                                                 Multiple Housing – Type 2 (Duplex) will
                                                                                       not adversely impact on existing or
AND                                                                                    future electricity supply.

O2 All uses and works maintain an          S2.1 Development for uses adjacent to       Not Applicable
adequate safe distance from electrical     or within 50m of an existing electricity
infrastructure including substations,      substation     incorporates      noise
overhead powerlines, power poles and       attenuation measures to mitigate noise
transformers.                              impacts;

                                           AND

Used in these records

About this file

File size
445 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment A - Code Assessment [As Published].pdf · 445 KB (small file)