Original source · versioned page text
Attachment 13 - Code Assessment
Performance outcomes Acceptable outcomes Response
acoustic barriers and building façade treatment along
a. ≤60 dB(A) L10 (18 hour)
a portion of boundary interface with Myall Street.
façade corrected
(measured L90 (8 hour)
free field between 10pm
and 6am ≤40 dB(A))
b. ≤63 dB(A) L10 (18 hour)
façade corrected
(measured L90 (8 hour)
free field between 10pm
and 6am >40 dB(A))
2. in accordance with chapter 7 integrated noise
barrier design of the Transport Noise
Management Code of Practice – Volume 1
Road Traffic Noise, Department of Transport
and Main Roads, 2013.
Note: To demonstrate compliance with the acceptable
outcome, it is recommended that a RPEQ certified
noise assessment report is provided, prepared in
accordance with the State Development Assessment
Provisions Supporting Information – Community
Amenity (Noise), Department of Transport and Main
Roads, 2013.
If the building envelope is unknown, the deemed-to-
comply setback distances for buildings stipulated by
the local planning instrument or relevant building
regulations should be used.
In some instances the design of noise barriers and
mounds to achieve the noise criteria above the ground
floor may not be reasonable or practicable. In these
Page 10 of 23